background image

22

Alignment

Tips

•  Fine-tuning is best achieved by a pair of installers with a 

dedicated, two-way communication link: one installer makes 

adjustments on one airFiber radio while the other installer 

reports the received signal level at the other airFiber radio. 

Fine-tuning (see Fine-Tuning the Link) is necessary because 

the main lobe of the receiver is narrower than that of the 

transmitter, in both azimuth and elevation.

•  To accurately align the airFiber radios for best performance, you 

MUST align only one end of the link at a time.

•  For more convenient alignment, you may consider using 

long-range scopes (not included) temporarily attached to your 

airFiber radios.

•  You may need to use additional hardware to compensate for 

issues such as the improper orientation of a mounting pole or 
significant elevation differences between the airFiber radios.

Establishing a Preliminary Link

Adjust the positions of the Master and the Slave to establish a 
preliminary link. This requires the Master and Slave to be within a 
few degrees of the line of sight between the airFiber radios.

Note:

 The Master must be aimed first at the Slave because 

the Slave does not transmit any RF signal until it detects 

transmissions from the Master.

1.  For the Master and Slave, ensure the eight Lock Bolts on the 

Alignment Bracket are sufficiently loose by spinning each 

washer by hand.

WARNING:

 All Lock Bolts MUST be loose to avoid damage 

to the airFiber housing.

airFiber AF-24HD Quick Start Guide

Содержание airFiber 24 HD

Страница 1: ...24 GHz Full Duplex Point to Point 2 Gbps Radio Model AF 24HD...

Страница 2: ......

Страница 3: ...Carriage Bolts Qty 4 Flat Washers Qty 4 Split Lock Washers Qty 4 Hex Nuts Qty 4 Metal Strap 24 GHz Full Duplex Point to Point 2 Gbps Radio Model AF 24HD External GPS Antenna Cable Ties Qty 3 Gigabit...

Страница 4: ...2 Hardware Overview Side 0 5 10 5 10 Alignment Bracket Elevation Adjustment Azimuth Adjustment Ground Bonding Point Lock Bolts Lock Bolts airFiber AF 24HD Quick Start Guide...

Страница 5: ...3 Back Lock Bolts Lock Bolts Lanyard Loop Lanyard Loop Azimuth Adjustment Lock Bolts Lock Bolts Cover Lock Port Cover Elevation Adjustment Hardware Overview...

Страница 6: ...the unit is powered on DATA 10 100 1000 Mbps port handles all user traffic AUX Port for audio tone aiming LED Display Digital display used for power status and mode information CONFIG 10 100 Mbps secu...

Страница 7: ...Long Flash 6x 64QAM MIMO On 8x 256QAM MIMO LED Display RX Power dBm Number Decodable RX Signal Flashing Number Undecodable RX Signal Overload Condition Master Slave Off Slave Mode On Master Mode RF L...

Страница 8: ...ARNING Failure to properly ground your airFiber units will void your warranty Recommended 2 Outdoor Gigabit PoE surge protectors Ubiquiti Ethernet Surge Protector model ETH SP Note For guidelines abou...

Страница 9: ...an Ethernet cable between your computer and the CONFIG port Configure device settings in the airFiber Configuration Interface Once configuration is complete disconnect the cables to move the airFiber...

Страница 10: ...end of the Ethernet cable from the DATA port to the Ethernet port labeled POE on the Gigabit PoE Adapter 4 Connect the Power Cord to the power port on the Gigabit PoE Adapter Connect the other end of...

Страница 11: ...st of higher latency and throughput Full duplex operation provides the highest throughput and lowest latency however you have fewer frequency management options Half Duplex default The TX and RX Frequ...

Страница 12: ...your web browser Type http 192 168 1 20 in the address field and press enter PC or return Mac https 192 168 1 20 4 The login screen will appear Enter ubnt in the Username and Password fields Select y...

Страница 13: ...ave c For the Duplex drop down Half Duplex The default mode The TX and RX Frequencies can be the same or different to suit local interference Full Duplex The TX and RX Frequencies should be different...

Страница 14: ...pply 9 In Band Management is enabled by default so each airFiber radio must have a unique IP Address If the airFiber radios use the same IP Address then you may lose access to the airFiber radios via...

Страница 15: ...e The mounting assembly can accommodate a 51 101 mm 2 0 4 0 pole a Orient the Pole Mount Bracket around the pole so it is aimed in the direction of the other airFiber AF 24HD b Insert the Carriage Bol...

Страница 16: ...emove the eight Lock Bolts located on the Alignment Bracket 4 Ensure that there is a 6 mm gap between the head of each M8x14 Serrated Flange Screw and the Alignment Bracket 0 5 10 5 10 6 mm airFiber A...

Страница 17: ...r M8x14 Serrated Flange Screws with the slots on the Pole Mount Bracket Seat the screws in the slots Securely tighten the screws WARNING To prevent injury ensure that all four screws are seated and fu...

Страница 18: ...replace the nut to secure the wire c Secure the other end of the ground wire to a grounded mast pole tower or grounding bar WARNING Failure to properly ground your airFiber units will void your warra...

Страница 19: ...lear view to the sky and is above and as far away as possible from the AF 24HD 1 Attach the GPS Antenna Mount to a pole using the included Metal Strap or attach it to a wall using the appropriate fast...

Страница 20: ...GPS Antenna to the mount with a Cable Tie 4 Turn the Cover Lock counterclockwise to the Unlocked icon Slide the Port Cover down to remove it 5 Connect the External GPS Antenna to the GPS SMA connecto...

Страница 21: ...Create a strain relief for the Ethernet cable by feeding a Cable Tie through the tie slot under the cable Then wrap the Cable Tie around the cable and tighten 3 Connect the other end of the Ethernet...

Страница 22: ...end of the Power Cord to a power source Note For added protection we recommend installing two surge surpressors such as the Ubiquiti Ethernet Surge Protector model ETH SP Install the first surge prot...

Страница 23: ...ors installed 0 5 10 5 10 Ground to Pole Tower or Grounding Block Max 1 m from Ground Bonding Point External GPS Antenna Max 1 m Outdoor Gigabit PoE Surge Protector ETH SP Outdoor Gigabit PoE Surge Pr...

Страница 24: ...ched to your airFiber radios You may need to use additional hardware to compensate for issues such as the improper orientation of a mounting pole or significant elevation differences between the airFi...

Страница 25: ...a Loosen the Hex Nuts b Adjust the Pole Mount Bracket and Pole Clamps c Tighten the Hex Nuts 0 5 10 5 10 Hex Nuts 4 Slave Aim the Slave at the Master to achieve the strongest received signal level on...

Страница 26: ...djustment Bolt of the Master through its adjustment range Master Azimuth AZ Adjustment Bolt b Sweep the Elevation EL Adjustment Bolt of the Master through its adjustment range Master Elevation EL Adju...

Страница 27: ...ft and 800 m 2 625 ft Target 40 dBm Decrease RX Gain to overcome overload condition For short ranges or strong signal conditions adjust the power to be 3 5 dB below overload condition Decrease RX Gai...

Страница 28: ...her installer sees the strongest received signal level displayed on the LED Display of the Slave 3 Repeat steps 1 and 2 until you achieve a symmetric link with the received signal levels within 1 dB o...

Страница 29: ...ce and audio tone methods The User Guide is available at www ubnt com download airfiber Installer Compliance Responsibility Devices must be professionally installed and it is the professional installe...

Страница 30: ...dwidth 100 MHz Max Power Consumption 50W Power Supply 50V 1 2A PoE Gigabit Adapter Included Power Method Passive Power over Ethernet 42 58VDC Certifications CE FCC IC Mounting Pole Mount Kit Included...

Страница 31: ...ed only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do no...

Страница 32: ...ves or as approved by Ubiquiti Networks in writing II has been painted rebranded or physically modified in any way III has been damaged due to errors or defects in cabling IV has been subjected to mis...

Страница 33: ...POSE AND NON INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS...

Страница 34: ...ties or conditions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states and provinces do...

Страница 35: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may...

Страница 36: ...ormation Dish antenna TX Gain 33 dBi CAN ICES 3 A NMB 3 A Le pr sent appareil est conforme aux CNR d ISDE Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deu...

Страница 37: ...may be required to take adequate measures CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it This equipment is intended to be...

Страница 38: ...where you purchased the product Deutsch Die Europ ische Richtlinie 2012 19 EU verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol versehen ist nicht zu...

Страница 39: ...tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bonne et du...

Страница 40: ...conformity is available at the following internet address www ubnt com compliance Eesti keel Estonian K esolevaga deklareerib UBIQUITI NETWORKS et k esolev raadioseadme t p AF 24HD vastab direktiivi...

Страница 41: ...AF 24HD jest zgodny z dyrektyw 2014 53 UE Pe ny tekst deklaracji zgodno ci UE jest dost pny pod nast puj cym adresem internetowym www ubnt com compliance Portugu s Portuguese O a abaixo assinado a UB...

Страница 42: ......

Страница 43: ......

Страница 44: ...trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners Support help ubnt com Communit...