Ubiquiti air Grid M2 AGM2-HP-1114 Скачать руководство пользователя страница 12

10

airGrid

 AGM2-HP-1114 Quick Start Guide

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

3.  This equipment is provided with a detachable power cord which has 

an integral safety ground wire intended for connection to a grounded 
safety outlet.

a.  Do not substitute the power cord with one that is not the provided 

approved type. Never use an adapter plug to connect to a 2-wire 

outlet as this will defeat the continuity of the grounding wire. 

b.  The equipment requires the use of the ground wire as a part of the 

safety certification, modification or misuse can provide a shock 

hazard that can result in serious injury or death.

c.  Contact a qualified electrician or the manufacturer if there are 

questions about the installation prior to connecting the equipment.

d.  Protective earthing is provided by Listed AC adapter. Building 

installation shall provide appropriate short-circuit backup 

protection.

e.  Protective bonding must be installed in accordance with local 

national wiring rules and regulations.

General Warranty

UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and 

warrants that the Products furnished hereunder shall be free from defects 

in material and workmanship for a period of one (1) year from the date 

of shipment by UBIQUITI NETWORKS under normal use and operation. 

UBIQUITI NETWORKS sole and exclusive obligation under the foregoing 

warranty shall be to repair or replace, at its option, any defective Product 

that fails during the warranty period. The expense of removal and 

reinstallation of any item is not included in this warranty.
The foregoing warranty is exclusive and in lieu of all other warranties, 

express or implied, including the implied warranties of merchantability and 

fitness for a particular purpose and any warranties arising from a course 

of dealing, usage or trade practice with respect to the products. Repair or 

replacement in the manner provided herein shall be the sole and exclusive 

remedy of Buyer for breach of warranty and shall constitute fulfillment 

of all liabilities of UBIQUITI NETWORKS with respect to the quality and 

performance of the Products. UBIQUITI NETWORKS reserves the right 

to inspect all defective Products (which must be returned by Buyer to 

UBIQUITI NETWORKS factory freight prepaid).

Содержание air Grid M2 AGM2-HP-1114

Страница 1: ...2 2 4 GHz High Performance Integrated InnerFeed Antenna Model AGM2 HP 1114...

Страница 2: ......

Страница 3: ...tents 2 2 4 GHz High Performance Integrated InnerFeed Antenna Model AGM2 HP 1114 11x14 Grid Reflector Antenna Feed Feed Support Quick Start Guide L Bracket Pole Clamp M6 U Bolt M6x20 Bolts Qty 4 M6 Se...

Страница 4: ...visit www ubnt com toughcable Hardware Installation 1 Attach the Feed Support and L Bracket to the Grid Reflector a Orient the Grid Reflector for the appropriate polarization horizontal or vertical W...

Страница 5: ...3 Hardware Installation 2 Route an Ethernet cable through the cable opening of the Feed Support and connect it to the Ethernet port on the back of the Antenna Feed...

Страница 6: ...Horizontal Polarization Vertical Polarization WARNING The orientation of the Antenna Feed and Grid Reflector must match the orientation required for your signal polarization horizontal or vertical 4 W...

Страница 7: ...commodate a 1 25 2 2 pole a Ensure that the cable opening of the Feed Support faces down b Insert the M6 U Bolt into the Pole Clamp and L Bracket c Secure the M6 U Bolt with two M6 Serrated Flange Nut...

Страница 8: ...he Ethernet cable from the airGrid to the Ethernet port labeled POE on the PoE Adapter 2 Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 3 Connect the Power...

Страница 9: ...static IP address on the 192 168 1 x subnet 3 Launch your web browser and type http 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the User...

Страница 10: ...ler Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory require...

Страница 11: ...1 5 1 Wind Survivability 125 mph Wind Loading 5 lbf 100 mph ETSI Specification EN 302 326 DN2 Shock and Vibration ETSI300 019 1 4 Certifications FCC IC CE Operating Temperature 30 to 75 C Operating H...

Страница 12: ...Building installation shall provide appropriate short circuit backup protection e Protective bonding must be installed in accordance with local national wiring rules and regulations General Warranty U...

Страница 13: ...uct has been properly installed and used at all times in accordance and in all material respects with the applicable Product documentation IV All Ethernet cabling runs use CAT5 or above shielded cabli...

Страница 14: ...r users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication This device complies wit...

Страница 15: ...if a restriction on use applied to the product and it must follow the CE marking RoHS WEEE Compliance Statement English European Directive 2002 96 EC requires that the equipment bearing this symbol o...

Страница 16: ...ad suya desechar este y cualesquiera otros aparatos el ctricos y electr nicos a trav s de los puntos de recogida que ponen a su disposici n el gobierno y las autoridades locales Al desechar y reciclar...

Страница 17: ...ice overholder de v sentlige krav og vrige relevante krav i direktiv 1999 5 EF Nederlands Dutch Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device in overeenstemming is met d...

Страница 18: ...evanti li hemm fid Dirrettiva 1999 5 EC Norsk Norwegian UBIQUITI NETWORKS erkl rer herved at utstyret UBIQUITI NETWORKS device er i samsvar med de grunnleggende krav og vrige relevante krav i direktiv...

Страница 19: ......

Страница 20: ...Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks...

Отзывы: