background image

EasyCoder 501/601 – Installation Instructions

6

Pin

"uart3:"

Remarks

Pin

In/Out connector Remarks

DB25 female

DB15 female

1

GNDC

Cable shield

1

OUT 201

See example below

2

TXDB

Transmitted data from printer

2

OUT 201

3

RXDB

Received data to printer

3

OUT 202

4

RTSB

RTS from printer

4

OUT 202

5

CTSB

CTS to printer

5

OUT 203

6

DRSB

DSR to printer

6

OUT 203

7

GNDI

Signal ground

7

OUT 204

8

not used

8

OUT 204

9

not used

9

IN 101

See example below

10

not used

10

IN 101

11

not used

11

IN 102

12

not used

12

IN 102

13

not used

13

IN 103

14

not used

14

IN 104

15

not used

15

IN 103/104

16

+5VEXT

+ 5V max 200 mA*

17

not used

18

not used

19

not used

20

DTRB

DTR pemanently high

21

not used

22

not used

23

not used

24

not used

25

not used

  */. If strap fitted on P-1

INDUSTRIAL INTERFACE KIT, cont'd.

Connector Configuration

"uart3:" is a DB25 female connector.
The In/Out connector is a DB15 female connector.

The mounting holes are connected to chassis ground.

OUT

 signals are controlled by means of

PORTOUT (<nexp>) ON|OFF

 statements.

IN

 and 

OUT

 signals are read by means of

PORTIN (<nexp>)

 functions.

Also see UBI Fingerprint Programmer's Manual.

IN1

9

10

P-3

TIL193B

R5

R6

C10

Example of an IN port

Example of an OUT port

+5V

1

2

P-3

REL1

1

OUT1

P-2

3 2

POWER: max. 240VA
VOLTAGE: max. 60VAC
CURRENT: max. 4A

VOLTAGE: 10–48V
CURRENT: 3–16mA

Information in this manual is subject to change without prior notice and does not represent a commitment