• If you do not solve the problem after checking these points, cut off the power
supply at the main electrical panel and contact our customer service (see the
“Limited warranty” section to obtain the phone numbers).
MAINTENANCE
TROUBLESHOOTING
8
Do not use cleaning products identified with these symbols:
• Note that there is electrical current linked to the unit even if the thermostat is set off.
This means that there is a risk of electric shock as long as the unit is energized.
PROBLEM
DEFECTIVE PART OR PART TO CHECK
The unit does not work
- Defective thermostat or wrong thermostat setting
- Open circuit breaker or fuse
- The thermal protection has been activated
- Faulty connections
The unit runs continuously
- Defective thermostat or wrong thermostat setting
- Heat losses higher than the unit capacity
The enclosure is extremely hot
- Defective thermal protection
- Blocked air vents
- Defective motor
The unit cycles under control
of the thermal protection
(overheat indicator)
- Blocked air vents
- Defective motor
Overheating
- Defective motor
- Defective thermostat or wrong thermostat setting
The breaker trips when the
heater is turned on
- Faulty connections
- Voltage higher than that written on the nameplate
Elements are on, but the motor
does not work
- Defective motor
The desired room temperature
cannot be reached
- One or more elements are defective
- Defective thermostat or wrong thermostat setting
- Voltage lower than that written on the nameplate
- Heat losses higher than the unit capacity