1. Press the "TIMER" key in operating mode status to set the desired time. 

2. Once the set time has elapsed, the unit will turn off automatically. 

3. If you press the "POWER" key before the time has been elapsed, the set time will be 

cancelled and the unit will turn off. 

8. SLEEP CONTROL FUNCTION 

1. In sleep comfort mode under the cooling setting - the temperature will be increased by 1ºC after 1 

hour. Subsequently, the temperature will be increased by 2ºC after 2 hours. It will maintain this 

setting without further changes. 

2. Under dehumidification mode, sleep mode cannot be selected. 

3. Low fan speed is the default setting under sleep comfort mode, but can be adjusted 

4. In sleep comfort mode heating setting, the temperature will be decreased by 1ºC after 

1 hour. Subsequently, the temperature will be decreased by 2ºC after 2 hours. It will 

maintain this setting without further changes. 

9. ALARM 

When the water tank is full,"E4" will be displayed on the display panel. To resume operation, 

please remove the rubber cap from the drain hose to drain out the water. After draining the 

water out, please restart the unit and then the unit can operate normally. 

 

 

 

 

 
 
 
 
 
 

8

 

REMOTE CONTROL FUNCTIONS 

The remote control uses two 

1.5 VOLT UM4 AAA CR03 

type batteries 

- Do not mix old and new batteries 

- Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, 

etc) batteries 

 

 
 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

Stop/Start switch 

MODE selector 

Time programming 

Automatic fan speed 

High fan speed 

Medium fan speed 

Low fan speed 

Sleep comfort mode selector 

Temperature selector 

Содержание 02435003

Страница 1: ...For help with product assembly to report damaged or missing parts or for any other information about this product please call our toll free number SAVE THIS MANUAL Keep this manual and the original s...

Страница 2: ...compressor will start after three minutes When switching to the heating function from the other modes the heating indicator light will flash for 3 5 minutes before the compressor and fan start up 10...

Страница 3: ...om on easy glide casters No installation required just plug into any household power outlet Refrigerated air system designed to cool instantly Heated air system design heats instantly Filtered air cir...

Страница 4: ...Indicates the temperature or the time setting After any time is set the display will return to the preset set temperature 6 SPEED Press to select LOW MEDIUM HIGH or AUTO fan speed If AUTO is selected...

Страница 5: ...ed 4 In sleep comfort mode heating setting the temperature will be decreased by 1 C after 1 hour Subsequently the temperature will be decreased by 2 C after 2 hours It will maintain this setting witho...

Страница 6: ...mance Please remove the air exhaust hose connect the drain hose to the drain hole and let the water drain into a container or outside When the water tank is full E4 will be displayed on the display pa...

Страница 7: ...in direct sunlight to avoid fading 12 HELPFUL HINTS The unit is fitted with a special thermal cut off device Please make sure the unit is not placed against objects that will obstruct air intake e g f...

Страница 8: ...Source 120V 60Hz Cooling Capacity 10 000 BTU hr Heating Capacity 10 000 BTU hr Refrigerant R410A Dimensions W x H x D 12 x 31 x 20 30 x 77 8 x 50 5 cm CE N 842 2006 R410A is a fluorinated greenhouse...

Страница 9: ...du panneau de contr le 5 7 4 T l commande 8 5 Avis 9 6 Entretien 10 7 Alimentation lectrique 11 8 Retrait et installation du tuyau d vacuation 12 9 Utilisation de la trousse pour fen tre 13 10 D pann...

Страница 10: ...r f rence CONSIGNES DE S CURIT 1 NE COUVREZ PAS LES OUVERTURES D A RATION Assurez vous que les grilles d entr e et de sortie d air de la ventilation sont d gag es en permanence 2 Installez l appareil...

Страница 11: ...unique CONSIGNES DE D BALLAGE 1 Avant de le d baller placer l appareil dans la position verticale qui convient 2 Couper les deux sangles de maintien 3 Soulever la bo te de fa on la faire glisser hors...

Страница 12: ...LA TEMP RATURE BAS En mode CLIMATISATION cette touche permet de baisser la temp rature de1 C la fois jusqu un minimum de 62 F 17 C En mode CHAUFFAGE cette touche permet de baisser la temp rature de 1...

Страница 13: ...suite la temp rature sera augment e de 2 C apr s deux heures Ce r glage sera maintenu sans autre changement 2 Cette fonction n est pas disponible en mode D SHUMIDIFICATION 3 Quand cette fonction est a...

Страница 14: ...nctionne 2 En mode de chauffage retirez le capuchon en caoutchouc du tuyau de drainage et installez le tuyau de drainage du diam tre int rieur de 17 mm fourni de fa on obtenir le meilleur chauffage po...

Страница 15: ...pas l appareil dans un endroit humide pour viter les risques d lectrocution N exposez pas l appareil directement aux rayons du soleil pour ne pas le d t riorer CONSEILS PRATIQUES L appareil est quip d...

Страница 16: ...uivre du capteur de temp rature et le c blage de la carte principale et circuit de la carte principale Communiquez avec le service la client le pour faire r parer l appareil E3 Fuite de r frig rant pa...

Страница 17: ...ication pour 36 mois suivant la date d achat Cette garantie n a aucune incidence sur vos droits l gaux En cas de mauvais fonctionnement de votre produit UBERHAUS bris pi ces manquantes etc veuillez ap...

Отзывы: