UAV-1000711-001 Rev E
ECN 7A994
Page
20 | 31
The transponder system should be configured during initial system
installation by a qualified technician. The configuration items list below
should be used to document the system installation for future reference.
Configuration Item
Default
Control
Priority
Default Control
Standby/Off
YES
ICAO Number
0x000000
Callsign
“ “
YES
Aircraft Category
UAV (14)
VFR Squawk Code
1200
YES
Aircraft Maximum Speed
Not Available
ADS-B RX Capability
UAT RX
NO
ES1090 RX
NO
Aircraft Length (Meters)
0
Aircraft Width (Meters)
0
GPS Offset Lateral (Meters)
0
GP Offset Longitudinal (Meters)
0
Configuration Items List
9.1 Default Control
Select the desired control type. This setting configures the Ping200Sr for
Standby, On or Altitude reporting.
•
Standby/Off: Disables both the transmit and receive functions.
•
ON: Responds to all interrogations and transmits ADS-B Extended
Squitter messages. Reports 0000 to altitude (Mode C) interrogations.
ALT: Responds to all interrogations and transmits ADS-B Extended
Squitter messages. Reports barometric altitude to Mode C
interrogations.
9.2 ICAO Number
The ICAO address is a 24-bit number issued to the aircraft by the
registration authority of the aircraft. These addresses are usually written as
a 6-digit hexadecimal number, although you may also encounter one