12 Environmental Qualification Forms
Nomenclature
EchoESX ADS-B Mode S transponder
Part Number
UAV-1001190-001
Manufacturer
uAvionix Inc
Address
300 Pine Needle Lane, Bigfork, MT 59911
Conditions
DO-160G
Section
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Category B2
Low temperature ground
survival
4.5.1
-55°C
Low Temperature Short-Time
Operating
4.5.1
-45°C
Low Temperature Operating
4.5.2
-45°C
High Temperature Operating
4.5.4
+70°C
High Temperature Short-Time
Operating
4.5.3
+70°C
High Temperature Ground
Survival
4.5.3
+85°C
Loss of Cooling
4.5.5
Cooling air not required (+55°C operating without
cooling)
Altitude
4.6.1
25,000feet
Decompression
4.6.2
Equipment identified as Category B2
– no test
Overpressure
4.6.3
Equipment identified as Category B2
– no test
Temperature Variation
5.0
Equipment tested to Category B
Humidity
6.0
Equipment tested to Category A
Operation Shock and Crash
Safety
7.0
Equipment tested to Category X
– no test
Vibration
8.0
Aircraft zone 2: type 5 Category S level M
Explosion
9.0
Equipment identified as Category X
– no test
Waterproofness
10.0
Equipment identified as Category X
– no test
Fluids Susceptibility
11.0
Equipment identified as Category X
– no test
Sand and Dust
12.0
Equipment identified as Category X
– no test
Fungus
13.0
Equipment identified as Category X
– no test
Salt Spray
14.0
Equipment identified as Category X
– no test
Magnetic Field
15.0
Equipment identified as Category Z
Power Input
16.0
Equipment identified as Category BX
Voltage Spike
17.0
Equipment identified as Category B
AF Conducted Susceptibility
18.0
Equipment identified as Category B
Induced Signal Susceptibility
19.0
Equipment identified as Category AC
RF Susceptibility
20.0
Equipment identified as Category TT
RF Emissions
21.0
Equipment identified as Category B
Lightening Induced Transient
Susceptibility
22.0
Equipment identified as Category XXXX
– no test
Lightening Direct Effects
23.0
Equipment identified as Category X
– no test
Icing
24.0
Equipment identified as Category X
– no test
Electrostatic Discharge
25.0
Equipment identified as Category X
– no test
Fire, Flammability
26.0
Equipment identified as Category X
– no test
Temperature and Altitude
4.0