1
1. IMPORTANT NOTICE
This manual contains important safety information
and precautionary measures. It is impossible to list
all potential hazards associated with every dust
collection system in each application. Proper use of
the equipment must be discussed with United Air
Specialists, Inc. (UAS) or your local Cyclone
representative. Operating personnel must be aware
of, and adhere to, the most stringent safety
procedures.
1.1 GENERAL CAUTIONS ON USING DUST
CONTROL EQUIPMENT
1. Avoid mixing combustible materials such as
aluminum, paper, wood or other organic dusts
with dusts generated from grinding or welding
metals. A fire hazard could develop from sparks
entering the dust collector. When collecting
flammable or explosive materials, the dust
collector should be located outdoors and
incorporate the appropriate safety measures
and/or accessories.
2. When collecting emissions from spark-producing
processes, care must be taken to reduce any
potential fire hazards. Dust collectors do not
contain fire extinguishing equipment unless
specifically ordered. Consult fire extinguishing
experts for recommendations concerning proper
fire detection and suppression systems.
3. Some dust collection systems require explosion
venting. Consult your insurance underwriter,
NFPA (National Fire Prevention Association)
Manual and local fire authorities to determine
requirements for explosion venting.
4. Be careful and conscientious—consult national
and local fire codes, waste disposal, safety and
other appropriate authorities. Comply with their
recommendations for proper installation and
operation of dust collection equipment.
2. INTRODUCTION
Thank you for selecting Cyclone dust collection
equipment to assist you in your commitment to a
clean and safe environment. We trust that in
purchasing our product you have recognized our
commitment to continually offer dust collection
equipment engineered to each dust collection need
and manufactured to the highest standards.
The UAS High Efficiency Cyclone Dust
Collector is designed to collect process-generated
dusts. The C-Series cyclone provides continuous-
duty operation in its application to improve the work
environment.
As you review this manual, refer to Figure 1 for
assistance locating unit parts.
2.1 UNIT NOMENCLATURE
Example: C3015-1D
2.2 DESCRIPTION AND OPERATION
C-Series cyclones are high-efficiency dust collectors
designed to eliminate airborne dust as it is
generated. Contaminants are captured at the
source(s), then conveyed through ductwork to the
collector where the dust is separated from the
airstream and collected.
The primary mode of operation is the air cleaning
operation. The separated dust is discharged into a
collection container. The clean air is then exhausted
into the atmosphere or further filtered through
afterfilters.
C
30
15
1D
High Efficiency Cyclone
Dust Collector
Refers to cyclone diameter
Horsepower of drive motor
Refers to single (1D) or dual
(2D drum discharge; or
hopper discharge (C60H/
C110H)
Revised 06/07
C-Series
Cyclone Dust Collector
Содержание C Series
Страница 1: ...High Efficiency C Series Cyclone Dust Collector OWNER S MANUAL ...
Страница 5: ...Figure 1 C Series Cyclone Dust Collector CYCFIG1 Revised 06 07 C Series Cyclone Dust Collector 2 ...
Страница 7: ...Figure 2 Typical Installation Diagram CYCFIG2 Revised 06 07 C Series Cyclone Dust Collector 4 ...
Страница 10: ...Figure 4 One and Two Drum Base Assembly CYCFIG4 5 Revised 06 07 C Series Cyclone Dust Collector 7 ...
Страница 11: ...Figure 5 C60H and C110H Hopper Base Assembly CYCFIG4 5 Revised 06 07 C Series Cyclone Dust Collector 8 ...
Страница 16: ...Figure 9 Remote Connection Afterfilter Assembly Revised 06 07 C Series Cyclone Dust Collector CYCFIG8 9 10 13 ...
Страница 19: ...Figure 13 Wiring Diagram 04 1534 Revised 06 07 C Series Cyclone Dust Collector 16 ...
Страница 31: ...28 Revised 06 07 C Series Cyclone Dust Collector This page intentionally left blank ...