U.S. Sunlight Ventilator Скачать руководство пользователя страница 2

page 2

Mounting the Fan

Sizing Requirements

  

See sizing chart to assure that you select the correct number  

of fans for your situation. Some attics have walled off or  

chambered areas that will require additional fans to properly  

vent the space.  

 

If you have any questions or concerns please feel free to call  

our customer service specialists at

 866-446-0966.  

 

For crawlspace applications use 1 fan for every 
1200 sq. ft. based on a 2.5 ft. height.

Determine your mounting application

  

One of the great features about the All Purpose Ventilator is the many mounting options.

 

Gable Vent

Static or Turbine Vent

Crawlspace Vent

If you have a tile roof and do not want 

to cut into the tiles, use the gable vent  

for mounting the fan.

Rather than removing the static or 

turbine vent, simply use the same 

opening.

If your crawlspace has too much moisture, 

increase the airflow and reduce moisture 

by installing near a vent opening.

Important Tip:  

To maximize airflow to the attic close off any unused 

static vents. Use tar paper and staples as shown.

Before you begin:

  

Loosen (but do not remove) the 8 nuts 

(fig1)

  

on the 4 mounting brackets 

(fig 2)

 so they can slide freely.

And remember:

 

Always note the orientation of the fan’s 

air flow relative to the vent opening.

4 mounting brackets

fig 2

fig 1

Loosen

1 Fan

1 Fan

2 Fans

2 Fans

2 Fans

1 Fan

2 Fans

3 Fans

4 Fans

4 Fans

2 Fans

3 Fans

4 Fans

5 Fans

6 Fans

How Many Fans Do I Need?

Low Slope

Up to 4/12

Medium Slope

5/12 - 8/12

High Slope

9/12 - 12/12

Attic Size

total sq. ft.

800

  

sq.ft.

1200

  

sq.ft.

1600

  

sq.ft.

2000

  

sq.ft.

2400

  

sq.ft.

Содержание Ventilator

Страница 1: ...f attached wire C Wall mounting brackets 2 ea D Cross braces 2 ea E Cross brace bolt and nut 2 ea F Mounting bracket bolt and nut 4 ea G 1 5 screws for fan mounting 8 ea Some models include a thermal switch in the fan assembly Power drill with phillips head driver and an 1 8 drill bit Adjustable wrench Measuring tape tip snips or wire cutters for cutting hole in vent screen Circular saw or handsaw...

Страница 2: ...tiles use the gable vent for mounting the fan Rather than removing the static or turbine vent simply use the same opening If your crawlspace has too much moisture increase the airflow and reduce moisture by installing near a vent opening Important Tip To maximize airflow to the attic close off any unused static vents Use tar paper and staples as shown Before you begin Loosen but do not remove the ...

Страница 3: ...en fastened slide the fan assembly into position pressing it firmly against the vent louvers and tighten the 8 nuts fig 6 fig 3 fig 4 fig 5 fig 6 Option 2 vent area requires additional mounting braces Step 1 Measure the distance between the 2 framing members that the braces will attach to fig 7 Step 2 Cut two 2x4 braces to the required length fig 8 Step 3 Locate the two braces between 14 25 and 15...

Страница 4: ...ews G Center the fan in the frame making sure that there is at least 4 of clearance between the fan housing and the crawlspace vent opening fig 22 fig 17 fig 18 fig 19 fig 20 fig 21a fig 22 Vent Opening 4 crawlspace outer wall ground vent opening box frame AIRFLOW inner dimension should be 14 5 Static or Turbine Vent Installation The All Purpose Ventilator can be used to push hot air out of your a...

Страница 5: ...ig 24 fig 25 fig 26 fig 27 Surface mounting for S Tile Flat Tile or Metal roofs Step 1 Determine the location of the contact points by positioning the panel in the desired area For S Tile roofs find a position with as much surface area coming in contact with the bottom of the panel as possible The panel must be mounted on at least 2 rows of tile as shown fig 28 29 Step 2 Apply enough roof tile adh...

Страница 6: ...p 1 Once the panel and fan are mounted route the wire from the panel to the fan attaching the wire to the building appropriately We suggest using romex mounting clips or coaxial staple for either wood or masonry available at your local hardware store or home builder supply fig 36 Step 2 Typically the wire will route through an opening in the vent or an unused louver fig 37 Step 3 Connect the wires...

Страница 7: ...n some models H thermal switch assembly 14 13 12 11 10 15 E F G 16 H Fascia Mount Optional With the optional fascia bracket kit the panel can be mounted directly to a fascia board Fascia mounting kit To order go to www ussunlight com or call 866 446 0966 fig 40b fig 40a fig 40d fig 40c Thermal Switch The thermal switch allows the fan to run when the temperature reaches 80 degrees and shuts the fan...

Страница 8: ..._______________________ Name of Installer ____________________________ self __ Phone of Installer ____________________________ Method of application Gable _____ Static _____ Crawl space _____ Comments _______________________________________________________________________________ ___________________ ___________________________________________________________________________________________________...

Отзывы: