Gas
& Electric Equipment Conversion Sheet
DATE:
MARCH 26 1998
MODEL #:
0836-1
SERIAL #:
042584T
TYPE OF GAS BEING USED PRESENTLY: PROPANE
EXISTING MANIFOLD PRESSURE: 10 "WC
ELECTRICAL RATING: N/A AMPS
N/A VOLTS
N/A PHASE
ELEVATION: UNDER 2000' CONVERSION REQUIRED: PROPANE -- NATURAL
NEW MANIFOLD PRESSURE:
5.0
"WC
COMPANY:
ELMER SHULTZ SERVICES
REQUESTED BY:
PETE
TELEPHONED
FAX#:
609 641 8703
It is recommended that a Garland Authorized Service Centre perform conversions.
Parts and special instructions necessary to complete the conversion are listed below:
Quantity
Part Number
Part Description
List Price ($) ea.
1
228052-9
REGULATOR NAT 1 1/4"
3
223242-50
GRIDDLE BURNER ORFICE
Special Instructions:
Please Note:
When converting a unit from one type of gas to another, the representative from the authority having jurisdiction
may request the rating plate be changed. If you any questions and/or concerns please call The Garland
Group Service Department at 1-800-427-6668