![U.S. Converters USC520 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/u-s-converters/usc520/usc520_user-manual_3092695035.webp)
USC520 / USC540 User Manual www.usconverters.com
U.S. Converters LLC 35 / 52 Copyrights © U.S.
Converters
Com
2
settings
FF
xx
08
[MAC]
[usrname]
[password]
COM
parameter
xx
USR
Cloud
0x10
[MAC]
[usrname]
[password]
Notice: Check bit is sum check, starts from length byte (including length) to adding before checking (not
including checking), result is check value, only low byte is remained.
1. Command examples
①
Search command example
Search command is set to:
FF 01 01 02
Sum check: 02 = 01 + 01
②
Reset command example
FF 13 02 d8 b0 4c 00 04 c9 61 64 6d 69 6e 00 61 64 6d 69 6e 00 c8
Sum check:
C8 = 13 + 02 + ... + 6E + 00
User name and password both are 5 bytes+00 bits 0 for the lack.
③
Read settings command example
Send (16 bytes)
:
FF 13 03 AC CF 23 66 66 67 61 64 6D 69 6E 00 61 64 6D 69 6E 00 F9
④
Save reading settings command example
Send (16 bytes)
:
FF 13 04 AC CF 23 66 66 67 61 64 6D 69 6E 00 61 64 6D 69 6E 00 FA
2. Some commands detailed annotation
①
Basic setting parameter command