![U-Prox IP500 Скачать руководство пользователя страница 12](http://html2.mh-extra.com/html/u-prox/ip500/ip500_installation-and-programming-manual_3080629012.webp)
12
As long as access point is in "Free Pass" mode, the lock is held in open position, the
panel stores a log event "Access granted" on presentation of RF ID code regardless
It is used to control the presence of personnel on the premises in case of an
emergency.
“Blocking" mode
If it is necessary to deny access to Access Point to all users of the system, the panel
switches into “Blocking" mode. If Access Point is in “Blocking" mode, the passage is
granted only to owners of RF IDs with the mark "Security Service". Access Point
may be opened by inner door handle.
Access point goes into “Blocking" mode after the operator command from the
computer. Access point is in “Blocking" mode until the command from the computer.
RF ID properties (cards)
Code (RF ID card code)
Each card has a unique code which is set at the time of its manufacture. It consists
of 10 hexadecimal digits.
Validity (of Card)
Card Validity expiration date
Alarm Cancel
Passing the card to door reader, when the door is in "Alarm" state, panel registers
event "Alarm cancelled" and puts the door to Normal mode. If the card that has no
right to cancel the “Alarm” is passed, the door will remain in the same state. “Access
denied. Alarm Status" event recorded into the log.
Security Service
Security Service mark gives the right of access to a blocked door.
When the ordinary card is passed if door is in "Blocking” Mode, "Access denied.
Blocked state” event recoded. Card with attribute “Security Service" pass. If the card
is valid and has access right at the moment, the panel gives access and event
“Access granted. Blocked state» is registered.
VIP
Access right to pass always everywhere, except through blocked door.
VIP card may be assigned any schedule, Antipassback and validity period is NOT
applied to it. The card may have PIN code
If the door is in “Blocked state", access is denied for RF ID with this attribute
checked.
The communicator
U-Prox IP500 Smart Handle panel operates automatically - after downloading data
from the server, it processes the card passed according to its access rights, grants
or denies access and sends event messages to the ACS server.
Warning !!! Timeout on receiving command from software can be up to one
period of the test signal, i.e., up to 2 minutes