http://u-prox.com 

Brief description of the panel 

U-Prox IP100  control panel - a device designed to control access to residential and 
business  premises,  for  pass  time  and  events  logging  and  analysis,  including 
personnel time attendance.  

The  defalt  modification  panel  has  built-in  proximity  card  reader  (ASK  and  FSK  RF 
IDs) and keyboard.  

The MF modification panel has built-

in card reader ISO14443A  (Mifare® Standard, 

Mifare® Hi-Memory, Mifare® Ultralight) and keyboard.  

U-Prox  IP100    processes  the  information  received  from  the  reader  (readers),  and 
controls actuator (e.g. a lock) with the built-in relay. 

Panel has two End-of-line supervised inputs. 

The  panel  can  work  offline  or  as  part  of  the  network.  To  add  it  to  Access  Control 
network,  Ethernet  (wired  computer  network)  or  Wi-Fi  (wireless  computer  network) 
interfaces are used.  

The network settings of the control panel are programmed via a standard USB port 
(mini USB B).  

Panel  U-Prox  IP100    has  advanced  hardware  capabilities  and  intellectual  functions 
to  control  a  single  door  with  one  built-in  reader  (single-sided  door)  or  two  readers 
(double-sided door). Having a large amount of non-volatile memory U-Prox IP100  is 
an access control system that provides for access control in variable establishments 
in  small  offices  as  well  as  on  large  enterprises  with  number  of  employees  up  to 
31768 and up to 1,000 visitors. 

Thoroughly elaborated technical and design solutions, the ability to connect external 
reader,  communication  over  a  computer  Ethernet  network  or  wireless  Wi-Fi,  non-
volatile  memory  and  the  clock, protecting  the  communication  ports  and  port  reader 
for short circuit, over-voltage and reverse polarity - all allows to use the panel to build 
a variety of Access Control Systems (ACS) - from the system for a small office to the 
entrance of a large enterprise. 

 

Intended use 

Panel  U-Prox  IP100    is  designed  for  operation  in  access  control  systems  (ACS)  of 
diverse scale in small offices as well as on large  enterprises. Panels are connected 
in ACS via computer network Ethernet or wireless Wi-Fi. 

The  panel  provides  access  to  one  room  with  the  ability  to  control  entry  and  exit  as 
well  as  an  alarm  system  of  rooms  connected  with  this  access point.  In  the  case  of 
simultaneous  control  of  entry  and  exit  from  the  rooms  function  "  Antipassback"  is 
provided (prohibition of re-runs). 

 

Содержание IP100

Страница 1: ...1 031 Access Control Panel U Prox IP100 Installation and programming manual...

Страница 2: ...djustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service cente...

Страница 3: ...th the device 20 Connection procedure 20 Installation recommendations 21 Installing Panel 21 Connecting an external reader 22 Connecting Loop Control 22 Request to Exit button RTE 23 Door Contact 23 C...

Страница 4: ...r or two readers double sided door Having a large amount of non volatile memory U Prox IP100 is an access control system that provides for access control in variable establishments in small offices as...

Страница 5: ...rvised inputs Built in Request to Exit button One relay contact NO NC COM 1 A 24 V One USB port to configure the network settings for connection to the ACS server Port Ethernet 4 wire 10 100 Mbps Wi F...

Страница 6: ...oor of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door Direction of passage Passageway is a logical unit...

Страница 7: ...exit or tries to enter somewhere from the area he have not enter System generates message GLOBAL ANTIPASSBACK Access Denied in case of global antipassback violation Door time If door sensor is open c...

Страница 8: ...Description and operation Panel The look of the access control panel is shown in Fig 1 and 2 Fig 1 U Prox IP100 panel Fig 2 U Prox IP100 components 3 4 2 1 1 Panel enclosure 2 RTE 3 LED 4 Keypad 7 1 1...

Страница 9: ...X 4 RX Sound and light panel Yellow LED Standby mode periodic blinking o 1 short pulse once per second communication Working in notification mode connection normal o 2 short pulse once per second comm...

Страница 10: ...is is the main mode of the panel In this mode the panel grants or denies access to RF ID owners In Normal mode the readers blink red Passing after entering RF ID To pass through user enters contactles...

Страница 11: ...e of people such as in the case of fire earthquake or in other emergency For this case the panel has Free Pass mode In Free Pass Mode LED of reader flashes green and yellow The access point goes into...

Страница 12: ...readers that have a built in keyboard Enter PIN code with the reader s keypad and press key Always enter PIN code AFTER the card pass If PIN code is correct panel unlocks access point and grants acces...

Страница 13: ...is in Alarm Mode impulse the output is activated for the programmed time trigger mode on the first event the output is activated on the following is off etc continuous The communicator U Prox IP100 p...

Страница 14: ...ra protection using VPN technology is recommend To provide backup communication channels use routers with two dissimilar channels of access to the Internet Working with multiple Wi Fi access points su...

Страница 15: ...nsion of reserved IP if DHCP 5 Determine accessibility of ACS server and U Prox IC A control panel IP or DNS name 6 Periodic sending test signals 7 If there is send the events Waiting for server comma...

Страница 16: ...ver and U Prox IC A control panel IP or DNS name 7 Periodic sending of test signals 8 If there is send the events Waiting for server commands 9 Failure transition to the second IP address of specified...

Страница 17: ...rded into the DB Panel becomes associated to the certain access control system server eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel...

Страница 18: ...tion unspecified is assigned when registering a new employee or after the system operator command location reset of person is fixed by U Prox IC A With the use of global antipassback it is possible to...

Страница 19: ...C F18 IP adjusting Only control panels with double sided doors entrance and exit on presentation of ID can be involved in global antipassback In configuraion server address 1 has to be the ACS server...

Страница 20: ...s from sensors buttons 7 Run the cable lead Ethernet if necessary 8 Run the wire commutation of power supply lock reader inputs of the panel with the loops in accordance with the sections below recomm...

Страница 21: ...st 20 cm from panel to eliminate the effect of double reading Installing Panel Loosen the screw at the bottom of panel Remove the upper lid remove the back plate Using the back plate of the panel as a...

Страница 22: ...nsumption more than 100 mA supply the voltage to it from the separate source Connecting Loop Control Panel has two inputs for connecting the loops supervised with end of line resistors Each input func...

Страница 23: ...Fig 15 Fig 15 Connection of RTE button Z1 input function assigned as follows Z1 RTE of access point A The use of button of the electric lock to open access point or allow access button on the turnsti...

Страница 24: ...combined loop connection to Z1 terminals is on the Fig 17 Fig 17 Connecting combined loop Z1 input function assigned as follows Z1 Combined door contact and RTE of access point A Any of two inputs ca...

Страница 25: ...or turns on and off any optional hardware with this output The example of actuator connection is on the Fig 19 The first is powering the lock and second by depowering Fig 19 Connecting locks When usi...

Страница 26: ...erver Panel communicator operates in notification mode If there is event passage input violation data transmission to ACS server is initiated Panel provides protection against arbitrary interference d...

Страница 27: ...nternet 2 optional o IP address of the DNS Server 1 if data transfer of the domain name is used o IP address of the DNS Server 2 optional if data transfer of the domain name is used Setting communicat...

Страница 28: ...P address of the gateway router to the Internet 2 optional o IP address of the DNS server 1 if a data transfer of the domain name o IP address of the DNS Server 2 optional if you are using a data on t...

Страница 29: ...refer to the software manual 4 Set up device with ACS software a Door settings Single sided or Double sided door operation of Antipassback Time of PIN entering or off b Access points settings no of re...

Страница 30: ...qual to 0 zero 5 Upload write the new configuration to the panel The controller will restart with factory settings Switching to programming mode To put panel in programming mode do the following 1 Do...

Отзывы: