1. 

Panel checks for DHCP mode ON (panel address 0.0.0.0) or static IP 

2. 

If DHCP mode is ON, the dynamic IP address obtain routine will start 

3. 

The panel automatic configuration mode starts if the access control system 
IP address (IP or DNS name) is not set: 

a. 

Panel  sends  data  packages  announcing  access  control  system 
server about itself as a new device in the local network 

Despite  it  is  broadcast  announcement,  it  is  limited  with  single 
range  local  network  and  active  network  equipment.  That’s  why 
the  IP  addresses  of  the  access  control  system  server  are  to  be 
set manually for networks with sophisticated topology. 

b. 

The  system  will  warn  operator  after  the  receiving  of  the  data 
package  from  the  new  panel.  Operator  must  add  panel  to  the 
system database (DB). 

c. 

After  the  panel  added  to  the  DB  it  receives  the  answer  from the 
access control system server. The address of the access control 
system  server  recorded  into  the  control  panel  and  it  stops  to 
broadcast. 

d. 

Operator  has  to  upload  panel  after  its  adjustment  recorded  into 
the DB. Panel becomes associated to the certain access control 
system  server,  eliminating  panel  control  capture  with  another 
system.  

Return  panel  to  the  factory  settings  to  eliminate  the  panel 
association to the system 

e. 

In  the  case  of  access  control  system  server  IP  address  change 
panel will initiate the automatic configuration routine, but the data 
exchange will be possible with previously connected system only.  

 

Global antipassback 

U-Prox  IP100  control  panel  can  operate  in  a  system  of  global  antipassback.  The 
main controller U-Prox IC A tracks the location of a person on the fact of its passage 
through  the  access  point.  U-Prox  IC  A  receives  data  about  the  passages  from 
control panels U-Prox IP400, NDC F18 IP, U-Prox IP100, U-Prox IP300. 

The  basis  of  the  global  antipassback  is  the  zoned  antipassback.  The  facility  is 
divided  into  rooms  -  zones  of  access  or  areas.  With  this  division  the  entrance  to 
another area is exit from the previous one, and the passage in the area is possible 
through various access points. 

Antipassback control panel receives data from the access control panels and tracks 
the movement of personnel from area to  area . Also can  be tracked the location of 
the person who has multiple IDs (See Figure 8). 

Содержание IP100

Страница 1: ...1 031 Access Control Panel U Prox IP100 Installation and programming manual...

Страница 2: ...djustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service cente...

Страница 3: ...th the device 20 Connection procedure 20 Installation recommendations 21 Installing Panel 21 Connecting an external reader 22 Connecting Loop Control 22 Request to Exit button RTE 23 Door Contact 23 C...

Страница 4: ...r or two readers double sided door Having a large amount of non volatile memory U Prox IP100 is an access control system that provides for access control in variable establishments in small offices as...

Страница 5: ...rvised inputs Built in Request to Exit button One relay contact NO NC COM 1 A 24 V One USB port to configure the network settings for connection to the ACS server Port Ethernet 4 wire 10 100 Mbps Wi F...

Страница 6: ...oor of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door Direction of passage Passageway is a logical unit...

Страница 7: ...exit or tries to enter somewhere from the area he have not enter System generates message GLOBAL ANTIPASSBACK Access Denied in case of global antipassback violation Door time If door sensor is open c...

Страница 8: ...Description and operation Panel The look of the access control panel is shown in Fig 1 and 2 Fig 1 U Prox IP100 panel Fig 2 U Prox IP100 components 3 4 2 1 1 Panel enclosure 2 RTE 3 LED 4 Keypad 7 1 1...

Страница 9: ...X 4 RX Sound and light panel Yellow LED Standby mode periodic blinking o 1 short pulse once per second communication Working in notification mode connection normal o 2 short pulse once per second comm...

Страница 10: ...is is the main mode of the panel In this mode the panel grants or denies access to RF ID owners In Normal mode the readers blink red Passing after entering RF ID To pass through user enters contactles...

Страница 11: ...e of people such as in the case of fire earthquake or in other emergency For this case the panel has Free Pass mode In Free Pass Mode LED of reader flashes green and yellow The access point goes into...

Страница 12: ...readers that have a built in keyboard Enter PIN code with the reader s keypad and press key Always enter PIN code AFTER the card pass If PIN code is correct panel unlocks access point and grants acces...

Страница 13: ...is in Alarm Mode impulse the output is activated for the programmed time trigger mode on the first event the output is activated on the following is off etc continuous The communicator U Prox IP100 p...

Страница 14: ...ra protection using VPN technology is recommend To provide backup communication channels use routers with two dissimilar channels of access to the Internet Working with multiple Wi Fi access points su...

Страница 15: ...nsion of reserved IP if DHCP 5 Determine accessibility of ACS server and U Prox IC A control panel IP or DNS name 6 Periodic sending test signals 7 If there is send the events Waiting for server comma...

Страница 16: ...ver and U Prox IC A control panel IP or DNS name 7 Periodic sending of test signals 8 If there is send the events Waiting for server commands 9 Failure transition to the second IP address of specified...

Страница 17: ...rded into the DB Panel becomes associated to the certain access control system server eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel...

Страница 18: ...tion unspecified is assigned when registering a new employee or after the system operator command location reset of person is fixed by U Prox IC A With the use of global antipassback it is possible to...

Страница 19: ...C F18 IP adjusting Only control panels with double sided doors entrance and exit on presentation of ID can be involved in global antipassback In configuraion server address 1 has to be the ACS server...

Страница 20: ...s from sensors buttons 7 Run the cable lead Ethernet if necessary 8 Run the wire commutation of power supply lock reader inputs of the panel with the loops in accordance with the sections below recomm...

Страница 21: ...st 20 cm from panel to eliminate the effect of double reading Installing Panel Loosen the screw at the bottom of panel Remove the upper lid remove the back plate Using the back plate of the panel as a...

Страница 22: ...nsumption more than 100 mA supply the voltage to it from the separate source Connecting Loop Control Panel has two inputs for connecting the loops supervised with end of line resistors Each input func...

Страница 23: ...Fig 15 Fig 15 Connection of RTE button Z1 input function assigned as follows Z1 RTE of access point A The use of button of the electric lock to open access point or allow access button on the turnsti...

Страница 24: ...combined loop connection to Z1 terminals is on the Fig 17 Fig 17 Connecting combined loop Z1 input function assigned as follows Z1 Combined door contact and RTE of access point A Any of two inputs ca...

Страница 25: ...or turns on and off any optional hardware with this output The example of actuator connection is on the Fig 19 The first is powering the lock and second by depowering Fig 19 Connecting locks When usi...

Страница 26: ...erver Panel communicator operates in notification mode If there is event passage input violation data transmission to ACS server is initiated Panel provides protection against arbitrary interference d...

Страница 27: ...nternet 2 optional o IP address of the DNS Server 1 if data transfer of the domain name is used o IP address of the DNS Server 2 optional if data transfer of the domain name is used Setting communicat...

Страница 28: ...P address of the gateway router to the Internet 2 optional o IP address of the DNS server 1 if a data transfer of the domain name o IP address of the DNS Server 2 optional if you are using a data on t...

Страница 29: ...refer to the software manual 4 Set up device with ACS software a Door settings Single sided or Double sided door operation of Antipassback Time of PIN entering or off b Access points settings no of re...

Страница 30: ...qual to 0 zero 5 Upload write the new configuration to the panel The controller will restart with factory settings Switching to programming mode To put panel in programming mode do the following 1 Do...

Отзывы: