Technical Data

 

Supply  :

 

 

 

Direct voltage with a ripple of max. 2V

SS

 

u::Lux NetCon 

48V 

u::Lux NetCon Power 

22V - 30V

 

Power consumption:

 

 

max. 1,5W (without connection of 

u::Lux Switch RJ45

 

 

 

 

max. 48 W (with connection of 2 x 10 pieces of 

u::Lux Switches RJ45

)

 

Connections:

   

 

1 x supply (+VCC or –VCC, Phoenix MSTB 2,5/ 2-ST-5,08 
2 x Ethernet RJ45 jacks with 48V supply (LAN1 and LAN2 -> each 
via Pins 4+5 [–VCC] and 7+8 [+VCC]) 
 
 

 

 
 
 
 
 
 

 

2 x Ethernet RJ45 jacks without 48V supply (LAN3 and LAN4) 
1 x ground connection (via metal bracket on the bottom of the 
housing)  

Displays:

 

At the network connections per port there is a yellow LED for 
„LINK“ or “ACTIVITY” and respectively a green LED for displaying 
the voltages VCC, 3V3 und 2x 48V.

 

Network:

 

 

 

100BaseT

 

Ambient temperature:

   

-10 °C to +40°C

 

Storage temperature:

   

-30 °C to +80°C 

 

Protection type:

  

 

IP30

 

Protection class:

 

 

III

 

Assembly type:

   

 

Vertical on horizontal top-hat rail (35mm)

 

Installation dimensions:

 

95mm x 35mm x 76mm 

Housing materials: 

UPPER PART: synthetic mat. LEXAN UL94-V0, self-extinguishing 
Colour: RAL 7035 light grey 
Ambient temperature: up to +100°C 
LOWER PART: synthetic mat. NORYL UL94-V0, self-extinguishing 
Colour: RAL 7021 black-grey 
Temperature range: up to +100°C 
FOIL: made of polyester DIN 42 115, fine grained 
Foil with sanded look, horizontal sanding direction  

Содержание NetCon

Страница 1: ...u Lux NetCon u Lux NetCon Power Manual www u lux com office u lux com Tel 43 662 450 351 13 Fax 43 662 450 351 16 u Lux GmbH Rechtes Salzachufer 42 5020 Salzburg Austria ...

Страница 2: ...07 01 10 2014 Page 2 10 Contents General Information 3 Mounting 3 Mounting order 5 Startup 5 Startup order 5 Practical example 6 Network wiring 7 Technical Data 8 Hazard warnings 9 CE marking 9 Guarantee 9 Ordering Information 9 Version Management 10 ...

Страница 3: ... NetCon and u Lux NetCon Power except in case of an explicit distinction between the models The energy supply of the u Lux NetCon is carried out via direct voltage through the connections VCC and VCC The voltage has to be sufficiently filtered max voltage ripples 2VSS and it must be within the following range u Lux NetCon 48V DC u Lux NetCon Power 22V 30V DC Mounting The mechanical assembly of the...

Страница 4: ...ote that these vents are not covered and a sufficient distance to adjacent components is kept The housing height is approx 80mm Please note that for the Ethernet connections on the front there will be added approx 50mm additionally to the housing depth Altogether a free installation depth of approx 130mm is necessary Please take this into consideration when selecting an appropriate junction box wa...

Страница 5: ...upply voltage to VCC see Chapter General Information Startup After connecting the power supply all green LEDs have to illuminate With these LEDs the presence of the following voltages is indicated 1 Energy supply with supply voltage VCC 2 Internal voltage generation 3 3 volts 3 Internal voltage generation 48 volts on ports LAN1 and LAN2 If a network cable is connected to each of LAN1 LAN4 and a ph...

Страница 6: ...l A maximum of 2x10 u Lux Switches RJ45 per u Lux NetCon Power can be supplied with energy Therefore 2 units of u Lux NetCon Power are required for the energy supply of all 40 u Lux Switches RJ45 The u Lux Switches RJ45 are connected to the ports LAN1 and LAN2 of the u Lux NetCon Power Both ports of LAN3 are connected to each other cascading One of the two LAN4 ports forms the connection to the co...

Страница 7: ...anual Version 1 07 01 10 2014 Page 7 10 Network wiring An u Lux Switch line may not exceed the total length of 200 m because of the cable resistance voltage drop We recommend not exceeding the max length of 50 m of a single sub segment ...

Страница 8: ... the bottom of the housing Displays At the network connections per port there is a yellow LED for LINK or ACTIVITY and respectively a green LED for displaying the voltages VCC 3V3 und 2x 48V Network 100BaseT Ambient temperature 10 C to 40 C Storage temperature 30 C to 80 C Protection type IP30 Protection class III Assembly type Vertical on horizontal top hat rail 35mm Installation dimensions 95mm ...

Страница 9: ... device fire or other dangers u Lux NetCon or u Lux NetCon Power are devices which do not correspond to the PoE standard CE marking The CE marking is exclusively addressed to the governmental supervising authorities of the Member States and facilitates the free movement of goods The CE marking does not represent any guarantee of specific features Guarantee The guarantee complies with the statutory...

Страница 10: ...eation of the document 1 01 17 12 2012 THSI Correction Release 1 02 18 12 2012 AK Correction Release 1 03 14 01 2013 KH Addition Network connections via patchpanel 1 04 21 01 2013 KH Addition Connections 1 05 14 01 2014 THSI Addition of new order numbers 1 06 07 07 2014 KH u Lux switch u Lux switch RJ45 1 07 01 10 2014 AK Contact updated ...

Отзывы: