background image

USER GUIDE

Door Swing 1

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Door Swing

Units have a zero clearance for the door to open 90°, 
when installed adjacent to cabinets. 

Stainless Steel and black and white models require 2-1/8" 
(54 mm) door clearance to accommodate the handle if 
installed next to a wall. 

Integrated models require 1/4" (6 mm) clearance if 
installed next to a wall. Allow for additional space for any 
knobs or pulls installed on the integrated panel/frame.

Wall

Wall

90

Door Swing

90

Door Swing

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

Содержание Wine Captain

Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series 1024WC 24 Wine Captain Model RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...Product Dimensions Side by Side Installation Anti Tip Bracket General Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Wood Trim Finishing Free Standing Kit Operating Instructi...

Страница 3: ...ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all ava...

Страница 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity a...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...he rear CAUTION Unit can NOT be installed behind a closed cabinet door Never remove the round grounding prong from the plug and never use a two prong grounding adapter Never use an extension cord to c...

Страница 9: ...duct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 24 610 mm 3 9 16 91 mm Not Including Handle...

Страница 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...

Страница 11: ...driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if applicable 5 Check to be sure the unit is level from front to back and side...

Страница 12: ...to make two starter holes and fasten the anti tip brackets to the floor using the screws provided 7 Place the unit back into position making sure the feet engage the anti tip brackets properly Check t...

Страница 13: ...adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be ge...

Страница 14: ...he condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Remove control knob 3 3 Loosen the screw 1 in the center 4 Remove grille 2 from unit Installi...

Страница 15: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...

Страница 16: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...

Страница 17: ...r gasket is not pinched on the hinge side of the door To align and adjust the door 1 Remove grille see GRILLE PLINTH INSTALLATION 2 Loosen do not remove top and bottom hinge screws 3 Align door square...

Страница 18: ...tch cabinet 5 Repeat for cabinet base Prepare door for reinstallation 1 Rotate door 180 to reverse 2 Remove gasket This will reveal mounting holes for the door light activation bracket 3 Remove door l...

Страница 19: ...90 do not require this step 1 Remove wine rack see WINE RACK INSTALLATION in Maintenance 2 Starting from the side that has the spacers previously unaltered units will be on the right hand side from th...

Страница 20: ...aining or finishing to prevent permanent damage to the inner liner of the unit Allow stain or finish to dry thoroughly at least 24 hours for each coat following the product manufacturer s instructions...

Страница 21: ...ly used when unit is not installed in surrounding cabinetry To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligni...

Страница 22: ...commends allowing the unit to run overnight before loading with product MECHANICAL DIAL CONTROL The control dial turns unit ON OFF and sets temperature This set point temperature is a base setting use...

Страница 23: ...er airflow to perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between...

Страница 24: ...he subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and...

Страница 25: ...he presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurate...

Страница 26: ...hat sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine...

Страница 27: ...n Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable...

Страница 28: ...zontal wine racks properly position the bottles so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustr...

Страница 29: ...ainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always...

Страница 30: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...

Страница 31: ...necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the con...

Страница 32: ...same time lift the matching right rack release lever up Pull the rack out until it is free of the tracks and the cabinet NOTICE Do not remove the track rails from the cabinet To insert rack in the cab...

Страница 33: ...cabinet interior and will compromise the precise temperature control of the unit 1 Find the light located at the top of the unit Grasp the edges of the light housing lens 1 opposite the exposed tab an...

Страница 34: ...ent from the unit 2 Disconnect the power cord from its outlet and leave it disconnected until the unit is returned to service 3 If ice is on the evaporator allow ice to thaw naturally CAUTION DO NOT u...

Страница 35: ...es Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compres...

Страница 36: ...erature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illum...

Страница 37: ...ervice com 3 The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration...

Страница 38: ...IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Li...

Отзывы: