U-Line Drawer Alignment

6

Checking Drawer Alignment

The unit’s drawers are aligned at the factory before shipment. 
However, their alignment could have been disturbed during 
shipment or during overlay panel installation. Check each drawer 
to confirm that it is aligned:

Side-to-Side

 — When viewed from the top, the drawer front 

should be square with the sides of the cabinet.

Front-to-Back

 — When viewed from the side, the drawer 

front should be straight with the cabinet’s sides, not cocked 
forward or back.

Top-to-Bottom

 — When viewed from the front, the drawer 

should be level horizontally.

Adjusting Drawer Alignment

WARNING

SHOCK HAZARD — The unit must be unplugged from 
the wall outlet during drawer removal, adjustment and 
re-installation.

Drawer Removal

1. Confirm that the unit is 

unplugged from wall outlet.

2. Unplug the drawer’s connection 

wiring (top drawer only).

3. Remove the mounting screws. 

4. Pull the drawer completely out 

of the unit.

CAUTION

Use care when handling the drawer. Drawer edges, drawer 
rail and the unit’s slide may be sharp.

IMPORTANT

IMPORTANT

Drawer adjustments are made by moving the slide that carries the 
drawer’s rail. Minor adjustments may be made by loosening one of 
the slide’s mounting screws, adjusting the slide and retightening the 
screw. Severe adjustments may be made by removing the slides’ 
mounting screws, drilling new mounting holes and remounting the 
slide.

Side-to-Side Adjustment

The drawer will need a Side-to-
Side Adjustment if, when viewed 
from the top, the drawer front is 
not square with the sides of the 
cabinet. This is caused by one of 
the slides being mounted too far 
forward on the unit’s liner.

Minor Adjustment:

Note: 

The mounting holes on the 

slide are slightly larger than the 

screws’ diameter. 

1. Loosen the slide’s mounting 

screws.

2. Push the slide backward.

3. Retighten the screws. 

Severe Adjustment:

Note: 

 The slides have extra 

mounting holes that may be used.

1. Remove the slide’s mounting 

screws.

2. Reposition the slide so it is the 

same distance from the front 
of the liner as the other slide. 
Measure to confirm.

3. Mark new drilling holes using 

different sets of mounting holes on the slide.

Note: 

Front location holes are shown. Corresponding rear holes 

will also need to be marked. 

4. Drill all the new holes with a #30 drill bit.

5. Remount the slide.

Front-to-Back Adjustment

The drawer will need a Front-to-
Back Adjustment if, when viewed 
from the side, the drawer front is 
cocked forward or back. This is 
caused by the front slide 
mountings not being level with 
the rear slide mountings.

7 Standard Drawers

Aligned

Side-to-Side

Aligned
Front-to-Back

Aligned

Top-to-Bottom

Mounting

Screw

Top View of Unit

Not Aligned Side-to-Side

Push Slide

Backward

Loosen

Mounting Screws

Mark and Drill New

Mounting Holes

Push Slide

Backward

Not Aligned Front-to-Back

Side View of Unit

Содержание WINE CAPTAIN 2275DWRCOL

Страница 1: ...t In Undercounter Leader Since 1962 2000 SERIES DRAWER MODELS REFRIGERATORS COMBO REFRIGERATOR FREEZER ICE MAKERS WINE CAPTAIN MODELS U LINE COM 2275DWRCOL C2275DWRS 2275DWRCS INSTALL GUIDE C2275DWROL...

Страница 2: ...onmental Requirements 5 Standard Drawers Checking Drawer Alignment 6 Adjusting Drawer Alignment 6 Re installation of Drawer 7 Drawer Panel Installation Custom 1 4 Drawer Panel Inserts 8 Drawer Panel P...

Страница 3: ...Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong...

Страница 4: ...d If installing a 3 4 Full Overlay panel 3 4 overlay frame material Cutting Tools Drill Drill Bits If installing 1 4 Panel Insert 1 4 thick door panel material Cutting Tools Exterior Cleaning Overlay...

Страница 5: ...polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is usually not...

Страница 6: ...ck Stainless Steel 33 7 8 24 23 3 8 3 7 8 23 1 4 33 7 8 24 3 7 8 33 7 16 23 3 8 23 15 16 3 7 8 Stainless 2275DWRW C2275DWR 2275DWRC Black Stainless Steel 33 7 8 24 23 3 8 3 7 8 23 1 4 33 7 8 24 3 7 8...

Страница 7: ...5A circuit normal household current See Electrical Specifications Water Supply The unit requires a 1 4 inch OD water supply line and a shut off valve For more information see Page 12 Environmental Req...

Страница 8: ...the slides mounting screws drilling new mounting holes and remounting the slide Side to Side Adjustment The drawer will need a Side to Side Adjustment if when viewed from the top the drawer front is...

Страница 9: ...oosen one slide s mounting screws 2 Push the slide upward or downward to match the position of the other slide 3 Retighten the screws 4 Repeat the procedure with the other slide if necessary Severe Ad...

Страница 10: ...el insert into 1 4 inch channel in drawer front 6 Holding drawer gasket out of the way replace handle on drawer making sure it is seated properly on insert and that screw holes line up 7 Install two s...

Страница 11: ...Attach the drawer panel to the overlay panel using 10 x 5 8 wood screws and nylon spacers The nylon spacers fit between the overlay panel and the door panel as shown in Figure 11 The spacers allow th...

Страница 12: ...led in such a manner that the grille assembly can still be removed from the unit Screw Mount Recommended 1 Remove the grille from your unit by removing the two mounting screws See below 2 Lay the back...

Страница 13: ...U Line Grill Overlay Installation 11 1 4 8 1 2 3 3 32 19 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 7 16 5 16 10 5 16 11 64 2 1 8 1 2 22 7 8 23 7 8 FULL R Grille Overlay Dimensions 24 Inch Models Grille Drawing...

Страница 14: ...route the tubing to the appliance Leave approximately 8 of water line to be coiled behind the appliance The water line should be looped into 2 coils This will allow the line to flex when removing the...

Страница 15: ...each corner Remove the appropriate screws for horizontal or vertical mounting Do not discard 2 Insert the screws through the anti tip bracket B and attach the bracket to the unit Tighten screws secure...

Страница 16: ...ss and hold the POWER icon on the display panel for aproximately ten seconds until the F symbol flashes and release U Line recommends that the unit be allowed to run overnight prior to loading the ref...

Страница 17: ...today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class product...

Отзывы: