12
PROBLEM POSSIBLE
CAUSE
REMEDY
Unit not cold enough.
Control set too
Turn control knob
warm
CLOCKWISE to set
Check temperatures
temperature colder:
(see introduction for
Allow 24 hours for
specific temperatures)
temperature to stabilize
Light staying on
Adjust door so light
switch bracket contacts
switch plunger: See
DOOR ADJUSTMENT
Airflow to front
Airflow must not be
grille blocked
obstructed to front grille.
See INSTALLATION
Dirty condenser
Clean condenser:
coils
See CLEANING AND
MAINTENANCE
Door gasket not
Adjust door: See
sealing properly
DOOR ADJUSTMENT
Unit is too cold.
Control set too cold
Turn control knob
COUNTER-CLOCKWISE
Check temperatures
to set temperature
(see introduction for
warmer: Allow 24 hours
specific temperatures)
for temperature to
stabilize.
No interior light
Loose or burned
Tighten or replace
out bulb
bulb: See BULB
REPLACEMENT.
Light won’t go out
Light on/off switch
Turn switch to off.
when door is closed
is turned to ON.
See LIGHT SWITCH
AND BULB.
Troubleshooting Guide
Never attempt to repair or perform maintenance on the unit
until the main electrical power has been disconnected.
!
!
DANGER
41739 Origins WC Body.qxd 10/22/03 1:40 PM Page 12