SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
USER GUIDE
u-line.com
To ensure the windings are not shorted, check the S
and R to ground.
EMX20CLC
Refrigerant
R600a
Voltage
115 - 127 VAC
Frequency
60 Hz
Run Cap
12μF/165 VAC
Start Winding
6.7 Ohm at 77°F
Run Winding
12.6 Ohm at 77°F
LRA
3.7 A
FLA
0.5 A
Starting Device
8EA14C
Overload
4TM142RFBYY-53
* All resistance readings are ±10%
Compressor Specifications 1