Cleaning

u-line.com

Cleaning

Stainless Models

Stainless door panels and handles can discolor when 
exposed to chlorine gas, pool chemicals, saltwater or 
cleaners with bleach.

Keep your stainless unit looking new by cleaning with a 
good quality all-in-one stainless steel cleaner and polish 
monthly. For best results use Claire

®

 Stainless Steel 

Polish and Cleaner. Comparable products are acceptable. 
Frequent cleaning will remove surface contamination that 
could lead to rust. Some installations may require cleaning 
weekly.

Do not clean with steel wool pads.

Do not use stainless steel cleaners or polishes on 
any glass surfaces.

Clean any glass surfaces with a non-chlorine glass 
cleaner.

Do not use cleaners not specifically intended for 
stainless steel on stainless steel surfaces (this 
includes glass, tile and counter cleaners).

If any surface discoloring or rusting appears, clean it 
quickly with Bon-Ami

®

 or Barkeepers Friend Cleanser

®

 

and a nonabrasive cloth. Always clean with the grain. 
Always finish with Claire

®

 Stainless Steel Polish and 

Cleaner or comparable product to prevent further 
problems.

Using abrasive pads such as Scotchbrite™ will 
cause the graining in the stainless steel to 
become blurred.

Rust not cleaned up promptly can penetrate the 
surface of the stainless steel and complete 
removal of the rust may not be possible.

Integrated Models

To clean integrated panels, use household cleaner per the 
cabinet manufacturer’s recommendation.

INTERIOR CLEANING

Disconnect power to the unit. 

Clean the interior and all removed components using a 
mild nonabrasive detergent and warm water solution 
applied with a soft sponge or non-abrasive cloth. 

Rinse the interior using a soft sponge and clean water.

Do not use any solvent-based or abrasive 
cleaners.

 These types of cleaners may transfer taste to 

the interior products and damage or discolor the lining.

DEFROSTING

Under normal conditions this unit does not require manual 
defrosting. Minor frost on the rear wall or visible through 
the evaporator plate vents is normal and will melt during 
each off cycle. 

If there is excessive build-up of 1/4" (6 mm) or more, 
manually defrost the unit.

Ensure the door is closing and sealing properly. 

High ambient temperature and excessive humidity can 
also produce frost. 

CAUTION

!

DO NOT use an ice pick or other sharp 
instrument to help speed up defrosting. These 
instruments can puncture the inner lining or 
damage the cooling unit. DO NOT use any type of 
heater to defrost. Using a heater to speed up 
defrosting can cause personal injury and 
damage to the inner lining.

21

Содержание UORE124

Страница 1: ...USER GUIDE SERVICE MANUAL Outdoor Collection UORE124 24 Solid Door Refrigerator...

Страница 2: ...ation Environmental Requirements Electrical Cutout Product Dimensions Side by Side Installation Anti Tip Bracket General Installation Grille Installation Door Swing Door Adjust Free Standing Kit Opera...

Страница 3: ...over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentatio...

Страница 4: ...th CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage DANGER This unit contains R600a Isobutane which is a...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are prese...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS 24 cutout width sufficient if door protrudes beyond adjacent cabinetry PRODUCT DIMENSIONS REAR 4 102 mm 7 178 mm 24 61...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water l...

Страница 11: ...s than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit af...

Страница 12: ...ING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille 2 from unit Inst...

Страница 13: ...ng Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wa...

Страница 14: ...door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Ma...

Страница 15: ...odel Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to on...

Страница 16: ...lt into a cabinet To install the kit 1 Remove grille see GRILLE INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligning holes of shell accessory with the holes on the...

Страница 17: ...for more details NOTICE Temperature displayed reflects actual temperature inside unit If the temperature displayed is different than selected the unit is progressing towards the selected temperature...

Страница 18: ...layed is the actual temperature inside unit Toggle between o F o C Hold and for 5 seconds The display will change units Enable Sabbath Mode Press and hold for 5 seconds and release The o F o C symbol...

Страница 19: ...ies U Line uses the following sizes Combinations of red and white bottles are used in Wine Captain Models and Beverage Centers NOTICE Restricting airflow may result in poor product performance product...

Страница 20: ...e shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place the shelf Place the shelf i...

Страница 21: ...ess steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated pan...

Страница 22: ...sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 A...

Страница 23: ...n environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the cond...

Страница 24: ...n the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and milde...

Страница 25: ...will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied or statutory Some states do not allow the...

Отзывы: