background image

USER GUIDE

u-line.com

Extended Non-Use

Extended Non-Use

VACATION/HOLIDAY, PROLONGED SHUTDOWN

The following steps are recommended for periods of 
extended non-use:

1.  Remove all consumable content from the unit.

2.  Disconnect the power cord from its outlet/socket 

and leave it disconnected until the unit is returned to 
service.

3.  Turn off the water supply.

4.  If ice is on the evaporator, allow ice to thaw naturally.

5.  Clean and dry the interior of the cabinet. Ensure all 

water has been removed from the unit.

6.  Disconnect the water and drain line (if applicable) 

making sure all water is removed from the lines.

7.  The door must remain open to prevent formation of 

mold and mildew. Open door a minimum of 2” (50 
mm) to provide the necessary ventilation.

WINTERIZATION

If the unit will be exposed to temperatures of 40°F (5°C) 
or less, the steps above must be followed. In addition, 
P60 drain pumps in clear ice machines must be drained 
according to the following procedure:

1.  Remove the drain pump from the ice machine.

2.  Drain the water in the pump’s reservoir by turning the 

pump upside down and allowing the water to drain 
through the pump’s inlet and vent tube fittings.

3.  After water is drained, reinstall the drain pump and 

reattach all connections.

For questions regarding winterization, please call 
U-Line at 414.354.0300.

CAUTION

!

Damage caused by freezing temperatures is not 
covered by the warranty.

Do not put anti-freeze in your unit.

23

Содержание UHWC115

Страница 1: ...USER GUIDE SERVICE MANUAL 1 Class UHWC115 15 Wine Refrigerator ...

Страница 2: ...l And Recycling Installation Environmental Requirements Electrical Cutout Product Dimensions Cutout Dimensions Grille Installation Door Adjust Interior Adjustments Maintenance Cleaning Extended Non Use Operating Instructions Control Operation Service Freezer Baskets Wine Rack Installation Parts ...

Страница 3: ...elect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please...

Страница 4: ...r or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service must be done by factory authorized service personnel Any p...

Страница 5: ...in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove the door s drawer s DANGER 5 ...

Страница 6: ...emperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops...

Страница 7: ...the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit break...

Страница 8: ...ctrical connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS 15 Cutout width sufficient if door protrudes beyond adjacent cabinetry PRODUCT DIMENSIONS REAR FRONT TOP SIDE 4 102 mm 7 178 mm 15 1 387 mm 34 1 870 mm to 35 1 889 mm Preferred location for electrical outlet is in an adjacent cabinet 24 610 mm 5 8 16 mm Power Cord 6 ft 183 cm 1 38 mm 3 7...

Страница 9: ...k Although not required you may choose to increase the overall cutout width for ease of installation The Modular 3000 Series units are engineered with a variety of adjustment features to help ensure a seamless installation Adjustable doors leveling legs and grille will assist in fine tuning the installation All 3000 Series models fully integrate into overlay face frame inset or European frameless ...

Страница 10: ... unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Slightly loosen three screws on bottom hinge 3 Remove two grille screws 4 Slide grille to the left and remove Installing the grille 1 Align cabinet and grille holes and secure but do not over tighten grille screws 3 2 Tighten three hinge screws 4 3 Connect power to unit WARNING 3 2 10 ...

Страница 11: ...r gasket is not pinched on the hinge side of the door To align and adjust the door 1 Remove grille see GRILLE PLINTH INSTALLATION 2 Loosen do not remove top and bottom hinge screws 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 Tighten bottom hinge screws 6 Tighten top hinge screws REVERSING THE DOOR Location of the uni...

Страница 12: ... 4 Remove four screws from hinge holes on the opposite side Reinstall into holes where the hinge was removed Take care not to scratch cabinet 5 Repeat for cabinet base Prepare door for reinstallation 1 Rotate door 180 to reverse 2 Align the flat edge of the hinge with the outer edge of the cabinet 3 Hold door to keep from falling 4 Tighten three screws 5 Align flat edge of the hinge with the outer...

Страница 13: ...ack see WINE RACK INSTALLATION in Maintenance 2 Starting from the side that has the spacers previously unaltered units will be on the right hand side from the factory remove 2 screws slide and spacer 3 Reinstall the slide with the original 2 screws 4 Remove 2 screws from the other side 5 Place the spacer in between the liner and slide 6 Install original hardware 7 Slide wine rack back into positio...

Страница 14: ...TROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and beverage centers only Adjust refrigerator set point Press and release When the F or C in the display is flashing press to adjust the set point temperature View temperature in unit Press together...

Страница 15: ... from unit Note Take care when removing rack to avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the rack have a thin coating which is used to block moisture and provide lubrication Use care when handling Wine Rack Installation 1 Insert empty rack into unit with one side tilted slightly downward until back pin is between front and rear rail supports 2 Tilt rac...

Страница 16: ...on the bottles so the wine remains in contact with the cork which ensures the cork does not become dry Racks are designed to accommodate typical 750ml wine bottles as follows UHWC515 15 Wine Captain Models UHWC518 18 Wine Captain Models UHWC524 24 Wine Captain Models 5 Class 24 Wine 7 Bottles 5 Class 15 Wine 4 Bottles 5 Class 18 Wine 5 Bottles 16 ...

Страница 17: ...ck moisture and provide lubrication Use care when handling Slide and Secure Storage Bin Installation 1 Insert empty storage bin frame into unit with one side tilted slightly downward until back pin is between front and rear rail supports 2 Tilt frame back to horizontal and line up 2 back pins with rear rail support Line up left side of frame with rear and front rail support Continue inserting fram...

Страница 18: ...OTICE Do not remove the track rails from the cabinet To reinstall 1 Align the left and right basket channels with the tracks in the cabinet Ensure an even track engagement on both sides by gently pushing the basket into the cabinet until it stops 2 Before reloading the basket ensure proper movement of the travel stops in the left and right track rails by pulling the basket out gently until it stop...

Страница 19: ...ning in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendations INTERIOR CLEANING Disconnect electric current to the unit Clean the interior and all removed components using...

Страница 20: ...e anything to force ice from the evaporator Damage may result 1 Switch the ice maker off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove the standpipe by lifting it up while using a slight back and forth motion to loosen it from the drain hole The water in the reservoir will flow down the drain 5 Re install the standpipe into...

Страница 21: ...r flows over the evaporator assembly ice mold Initially the water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will correct itself within the first 24 hours of operation NOTICE Discard all ice produced in the first harvest Should power to the unit be interrupted during the self clean cycle the complete cleaning cycle ...

Страница 22: ...e cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engagement on both sides by gently pushing the rack into the cabinet until it stops 2 Before reloading the rack ensure proper movement of the travel stops in the left and right track rails by pulling the rac...

Страница 23: ...or must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps above must be followed In addition P60 drain pumps in clear ice machines must be drained according to the following procedure 1 Remove the drain pump from the ice machine 2 Drain the w...

Страница 24: ...055 00 13 Evap fan w cover and screws 80 54005 00 14 Evaporator 80 54057 00 15 Evaporator cover 80 54045 00 16 Glass shelf 1 w brackets 80 54041 00 17 Grille w screws 80 54040 00 18 Hinge covers 2 pcs 80 54001 00 19 Hinge mounting hole covers 80 54024 00 20 Hinges 2 w screws and covers 80 54013 00 21 LED light strip and cover assy 80 54000 00 22 Leg Levelers 4 80 54019 00 23 Main board no wires or...

Отзывы: