background image

USER GUIDE

u-line.com

Cleaning

Under normal conditions cleaning should be done 
when the display shows 

CL

. You may initiate 

a cleaning cycle at any time by pressing and 
holding the clean button for 10 seconds. 

0 1

 will 

appear in the display indicating the start of the 
cleaning process.

You may override 

CL

 in the display without cleaning by 

pressing and holding the up, down, & light button for 10 
seconds. 

ICE

 will scroll in the display and the cleaning 

reminder ( 

CL

) will be reset for another approximate six 

month cycle. Failure to clean may reduce the quality 
and quantity of ice produced. Once the clean cycle 
begins, it can be canceled by pressing      three times. 
Press      once more to start making ice. The clean cycle 
will automatically cancel if user fails to activate control at 
steps 2, 3b, and 5b within 2 hours.

Required for cleaning:

•    Hose and funnel - provided with unit
•    Bucket and cleaning sponge
•    Clean potable water
•    SafeCLEAN Plus™ Cleaner 

 

(Part No. ULANUGGETCLEAN) 1-8oz. bottle  

 

included with unit

• 

 1 Water filter (if required)

Need more cleaner? Visit u-line.com

CAUTION

!

Use only SafeCLEAN Plus™ Cleaner. Use of any 

other cleaner may damage the finish of the 

evaporator and will void the warranty.

Follow safety and handling instructions printed 
on the SafeCLEAN Plus™ bottle.

Notice:

Select models include a water filter. The filter 

must remain in place when using and cleaning 

the machine. The filter is designed to filter out 

scale, sediment, particles and cloudiness as 

well as reduce chlorine and other off tastes 

and odors. U-Line recommends replacing the 

filter (Part No. ULANUGGETFILTER) when you 
clean your machine. The filter is available at          

u-line.com.

1.  Press and Hold       for 10 seconds

a.  

0 1

 will appear in the display

b.  Remove access shield
c.  Remove all ice in bin
d.  Remove any ice protruding from the ice dispenser       
 tube.

2.  Insert the end of the cleaning tube into the ice        

dispenser; slowly pour in approximately 1 quart of  
 hot (min. 100º F) potable water. This will melt ice 
inside the dispenser tube.  It is normal for some water 

to flow from the ice dispenser tube and exit from the 

vent tube while  pouring. Omit this step if no ice is in 
the   ice dispenser tube.

3.   Press and release

a.  

02

 will appear in the display

b.  Mix 4 ounces of SafeCLEAN Plus™ with 2 quarts of         
     potable water.

4.  Wait until 

03

 appears in the display

  a.  Using the funnel and cleaning tube, slowly pour              
   

3⁄4

 of the cleaning solution into the dispenser  

  

 

tube. Air and some water will exit the vent tube.     

   

Remove cleaning tube.

  b.   Press and release 

5

.  

04

 will appear in the display

a.  The machine will circulate the solution, cleaning    
 

and sanitizing the internal components, for                 

 

approximately 20 minutes.

b.  While the machine is circulating the cleaning  

 

   

 

solution, use 

1⁄2

 of the remaining cleaning solution      

    

      

and a sponge to wipe down the inside of the ice bin  

    

 

and scoop. Rinse with clean potable water.

Cl

Cleaning Tube

 and Funnel

Ice

Dispenser

Tube

Vent Tube

23

Содержание UHNP115

Страница 1: ...USER GUIDE SERVICE MANUAL 1 Class UHNB115 UHNP115 15 Nugget Ice Machine...

Страница 2: ...n Environmental Requirements Electrical Cutout Product Dimensions Side by Side Installation Water Hookup Drain Anti Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintena...

Страница 3: ...over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentatio...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...e of the unit with other adjacent cabinet doors you may need to alter the wall just behind the drain connection on the unit to accommodate the drain CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP...

Страница 9: ...on Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintaine...

Страница 10: ...looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation Connect to potable water supply only W...

Страница 11: ...nect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Thread water line through back panel hole with bushing 4 Locate water valve inlet and connect to valve 5 Tu...

Страница 12: ...low the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connections and fittings...

Страница 13: ...e installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump FACTORY IN...

Страница 14: ...r a proper fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4...

Страница 15: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 16: ...e unit the grille must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two s...

Страница 17: ...itional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for...

Страница 18: ...en each pair of Torx head screws both the upper and lower hinge plates 3 Square and align door as necessary 4 Tighten Torx head screws on hinge 5 Reinstall gasket into the channel starting at the corn...

Страница 19: ...h Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The F C symbol will flash Display will be lit and in...

Страница 20: ...production resumes This ensures a constant supply of fresh ice is always available The factory default ice setting is 0 which produces a firm and compact ice nugget U Line s exclusive U Choose ice ad...

Страница 21: ...u line com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected D...

Страница 22: ...signs that cleaning is necessary If the machine consistently requires more frequent cleaning consult a plumber to test the water quality and recommend appropriate treatment Clean surfaces with a mild...

Страница 23: ...ng and cleaning the machine The filter is designed to filter out scale sediment particles and cloudiness as well as reduce chlorine and other off tastes and odors U Line recommends replacing the filte...

Страница 24: ...funnel slowly pour 1 5 quarts 48 oz of clean potable water into the ice dispenser tube Air and some water will exit the vent tube d Install new water filter Press and rotate 1 4 turn clockwise e Press...

Страница 25: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 26: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: