Airflow & Product Loading

Restricting airflow may result in poor product 
performance, product failure, and uneven internal 
temperatures and may freeze contents.

• Do not block the front grille - no additional clearance

around sides, top or rear of unit is needed for ventilation

• Do not install behind a closed door

• When loading, leave space between internal fans, vents,

and side walls to allow air to circulate freely

NOTICE

AIRFLOW
External

PRODUCT LOADING

Bottles and cans come in many shapes and sizes. Not 

all bottles and cans will fit on every shelf and wine rack. 
Larger diameter champagne and Magnum bottles only fit 
on wine racks when noted on the product specifications. 

When determining capacities U-Line uses typical 12 oz. 
cans, 12 oz. bottles, 750 mL white wine and red wine 
bottles shown below.

Airflow and Product Loading

Typical Can

(12 oz)

4

(123 mm)

(66 mm)

2

 27⁄32”

 19⁄32”

Typical Bottle

(12 oz)

9”

5

2

 7⁄16”

 5⁄16”

(135 mm)

(64mm)

(229 mm)

Typical White 

Wine Bottle

11 

(298 mm)

(750 mL)

3

 ¾”

(184 mm)

(82 mm)

11 

 ¼”

 ¼”

Typical Red 

Wine Bottle

11

(302 mm)

8

3”

29⁄32”

¾”

(222 mm)

(750 mL)

(76 mm)

Typical

Champagne Bottle

(750 mL)

11⁄16”

7

¾”

11⁄16”

(299 mm)

(94 mm)

(195 mm)

11 

Magnum Bottle

(1.5 L)

13

10

3

 1⁄8”

(334 mm)

 11⁄32”

(263 mm)

 27⁄32”

(98 mm)

Internal

19

Содержание UHBV124-SG01A

Страница 1: ...USER GUIDE SERVICE MANUAL Model UHBV124 SG01A...

Страница 2: ...ation Door Swing Door Adjust Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Product Loading Recommended Wine...

Страница 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Страница 4: ...oderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do n...

Страница 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Страница 6: ...ures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating e...

Страница 7: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Страница 8: ...front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIO...

Страница 9: ...cording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown bel...

Страница 10: ...oles and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if...

Страница 11: ...ing s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is corre...

Страница 12: ...HARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille 2 from unit Installing the grille 1 Align cabinet and grille holes and secur...

Страница 13: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Страница 14: ...do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 T...

Страница 15: ...either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Remove pivot screw from hinge flip hinge over and install the pivot s...

Страница 16: ...abinet Available at u line com To install the kit 1 Remove grille see GRILLE INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligning holes of shell accessory with the...

Страница 17: ...more details NOTICE Temperature displayed reflects actual temperature inside unit If the temperature displayed is different than selected the unit is progressing towards the selected temperature Time...

Страница 18: ...conds The display will change units Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain...

Страница 19: ...es Not all bottles and cans will fit on every shelf and wine rack Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capaciti...

Страница 20: ...racks properly position the bottles so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustration below...

Страница 21: ...eel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels us...

Страница 22: ...tive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow t...

Страница 23: ...mental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser uni...

Страница 24: ...lever up Pull the rack out until it is free of the tracks and the cabinet NOTICE Do not remove the track rails from the cabinet To insert rack in the cabinet 1 Align the left and right rack channels...

Страница 25: ...evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open...

Страница 26: ...akes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before d...

Страница 27: ...ing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of th...

Страница 28: ...te Black N C 1 6 Evap Cond fan Light Evap temp Zone temp Door switch Compressor FUSE Programming U s e r I n t e r f a c e 42376_C If Applicable POWER CORD ASSEMBLY 220 240 VOLT PLUG LIVE BLACK 115V B...

Страница 29: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Страница 30: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Страница 31: ...SIONS ARE IN INCHES XX 03 XXX 015 X 1 HOLE 010 004 REMOVE BURRS AND SHARP EDGES TO 015 MAX INTERPRET DIM AND TOL PER ASME Y14 5M 1994 DO NOT SCALE DRAWING THIRD ANGLE PROJECTION THIS DRAWING IN DESIGN...

Страница 32: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Страница 33: ...ust observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fi...

Страница 34: ...pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system p...

Страница 35: ...is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the sy...

Страница 36: ...ll a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minu...

Страница 37: ...cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room te...

Страница 38: ...an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure...

Страница 39: ...istance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this tec...

Страница 40: ...OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor Displa...

Страница 41: ...ger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cycle Pow...

Страница 42: ...ctivated with button activation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES Defrost Duration Enter menu by pressing for more than 5 seconds Use or to increase reduce defrost duration Press to select...

Страница 43: ...e Thermistor If the zone thermistor in the unit fails the unit will continue to cool in a backup mode Self Preservation Mode to preserve the integrity of the contents The unit will otherwise operate n...

Страница 44: ...its defrost every 12 hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak utilize the Control Operation Service section and adjust unit to de...

Страница 45: ...ation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate efficientl...

Страница 46: ...cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge...

Страница 47: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Отзывы: