![U-Line UCNP115-SS01A Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/u-line/ucnp115-ss01a/ucnp115-ss01a_quick-start-manual_3784206005.webp)
QUICK START GUIDE
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Electrical
SHOCK HAZARD - Electrical Groundining
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle that
has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure to
consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended
receptacle location.
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The edges
could be sharp.
CAUTION
!
5
CAUTION
!
USER GUIDE
u-line.com
Water Hookup
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4” (6.35 mm)
compression fitting. U-Line recommends using accessory
water hook up kit – part # 80-54674-00. The kit includes
a 10’ (3 m) braided flexible water supply line and a brass
hose fitting.
Plumbing installation must observe all state
and local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
Water Supply
When connecting the water supply, please note the
following:
•
Water Mineral Content:
◦
TDS: greater than 5 ppm (mg/l) but less than
400 ppm (mg/l)
◦
Hardness: Less than 200 mg/l (12 gpg)
•
Not recommended for use with softened water
•
A TDS meter is included with your unit
•
Water Treatment Options
◦
TDS between 400-600 and/or hardness
between 13-20 can be treated by U-Line’s in-line water
filter accessories available at u-line.com or your local
dealer:
ULALINEFILTER — Standard
ULALINEFILTERL — Large
ULALINEFILTERHEAD — 3/8” NPT, initial
setup requires head & filter
•
Use bypass level 6
Water Quality
1-3 Users
4+ Users
400 TDS and/or 12
gpg hardness or less
Optional
Standard Filter
Change 1x per year
Optional
Large Filter
Change 1x per year
401-600 TDS and/or
13-20 gpg hardness
Required
Large Filter
Change 1x per year
Required
Large Filter
Change 2x per year
601+ TDS, and/or
21+ gpg hardness
Contact your local water professional
•
The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
•
The water line MUST have a shut-off valve in the
supply line.
•
The water line should be looped into 2 coils. This
will allow the unit to be removed for cleaning and
servicing. Make certain that the tubing is not pinched
or damaged during installation.
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The edges
could be sharp.
HOOKUP WATER
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the back panel.
CAUTION
!
CAUTION
!
CAUTION
!