USER GUIDE
u-line.com
General Installation
Install Tower on Countertop
(See template on next page)
Note: These instructions are designed for a standard 36" countertop application.
Note: For a customized fit, it may be necessary to acquire screws that are sized to
the thickness of your countertop.
1. Position keg refrigerator under countertop to determine the desired depth.
2. Use the dimensions from Diagram A to determine the center point of the tower
mounting hole.
3. Remove keg refrigerator from under countertop.
4. Use template to drill 4 mounting holes and drill 3-
1⁄8
" diameter hole through countertop.
5. Connect keg and infuser hoses to tower.
6. Pull down insulation inside tower far enough to extend into refrigerator - Diagram B.
7. Secure tower to countertop.
8. Remove hole cover from top of refrigerator.
9. Carefully slide refrigerator under countertop, taking care to insert hoses and insullation
as you go.
Front Face
of Unit
2
¾
”
(70 mm)
Hole Diameter
Power Cord
2”
(51 mm)
15”
(381 mm)
Rear Wall
24 ¼”
(616 mm)
12 ½”
(318 mm)
11 1⁄8”
(283 mm)
1 11⁄16”
(43 mm)
7 ½”
(19 1 mm)
Rear Wall
Countertop
11-1/8”
(283 mm)
Front edge of hole
to front face of
refrigerator
Diagram A
Diagram B
Insulation
6
12