background image

USER GUIDE

u-line.com

Control Operation-Service

MODEL LIST

Model #

Model

1

*HBV315-***1A

2

*HBV315-***2A

3

*HBV318-***1A

4

*HBV324-***1A

5

*HBV324-***2A

6

*HBV336-***1A

7

*HBV515-***1A

8

*HBV515-***2A

9

*HBV524-***1A

10

*HBV524-***2A

11

*HCL315-***1A

12

*HCL315-***2A

13

*HDR324-***1A

14

*HDR324-***2A

15

*HFZ324-***1A

16

*HFZ324-***2A

17

*HRE315-***1A

18

*HRE315-***2A

19

*HRE318-***1A

20

*HRE324-***1A

21

*HRE324-***2A

22

*HRE336-***1A

23

*HRE515-***1A

24

*HRE515-***2A

25

*HRE524-***1A

26

*HRE524-***2A

27

*HRE324-***1A

28

*HRE324-***2A

29

*HKR524-***1A

30

*HKR524-***2A

31

*HWC315-***2A

32

*HWC315-***1A

33

*HWC318-***1A

34

*HWC324-***2A

35

*HWC324-***1A

36

*HWC515-***2A

37

*HWC515-***1A

38

*HWC524-***1A

39

*HWC524-***2A

40

*HWC336-***1A

41

*HBD324-***1A

42

*HBD324-***2A

43

*HBD524-***1A

44

*HBD524-***2A

45

*HWD324-***2A

46

*HWD324-***1A

47

*HWD524-***2A

48

*HWD524-***1A

49

*HRF124-***2A

50

*HRF124-***1A

51

*HRI124-***2A

52

*HRI124-***1A

53

Nugget 1 Class

54

Grid Ice

55

Medical Refrigerator

56

Full size

57

Nugget 3 Class

PROGRAMMING THE UNIT TO CORRECT
MODEL NUMBER

1. Disconnect the unit from power source. 
2. Push and hold the U-Line button.
3. While still holding the U-Line button, plug the
   

 

unit into the appropriate power source.

4. When the flashing digits appear (3-5 seconds),

    use the up and down arrow buttons to select the
    appropriate model number*.        or 
   *(See Above “Model List”)
5. Press the light bulb button once. 
6. The display will blink, and then will appear as the
    programmed display.

52

Содержание UANP115

Страница 1: ...USER GUIDE SERVICE MANUAL ADA Collection UANB115 UANP115 15 Nugget Ice Machine...

Страница 2: ...neral Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Operating Instructions Control Operation Ice Airflow and Product Loading Service Quick Guide Troub...

Страница 3: ...over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentatio...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...binet doors you may need to alter the wall just behind the drain connection on the unit to accommodate the drain CUTOUT DIMENSIONS 15 Cutout width sufficient if door protrudes beyond adjacent cabinetr...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...The water line MUST have a shut off valve in the supply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubin...

Страница 11: ...sconnect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Thread water line through back panel hole with bushing 4 Locate water valve inlet and connect to valve...

Страница 12: ...low the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connections and fittings...

Страница 13: ...e installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump FACTORY IN...

Страница 14: ...r a proper fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4...

Страница 15: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 16: ...e unit the grille must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two s...

Страница 17: ...ng Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wa...

Страница 18: ...s not pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver...

Страница 19: ...odel Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to on...

Страница 20: ...h Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The F C symbol will flash Display will be lit and in...

Страница 21: ...production resumes This ensures a constant supply of fresh ice is always available The factory default ice setting is 0 which produces a firm and compact ice nugget U Line s exclusive U Choose ice ad...

Страница 22: ...u line com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected D...

Страница 23: ...signs that cleaning is necessary If the machine consistently requires more frequent cleaning consult a plumber to test the water quality and recommend appropriate treatment Clean surfaces with a mild...

Страница 24: ...ng and cleaning the machine The filter is designed to filter out scale sediment particles and cloudiness as well as reduce chlorine and other off tastes and odors U Line recommends replacing the filte...

Страница 25: ...funnel slowly pour 1 5 quarts 48 oz of clean potable water into the ice dispenser tube Air and some water will exit the vent tube d Install new water filter Press and rotate 1 4 turn clockwise e Press...

Страница 26: ...nt cleaning may be necessary WARNING Disconnect electric power to the unit before cleaningthecondenser DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged NOTICE DO...

Страница 27: ...t 4 Option 11 DC Output 5 Option 12 Serial output Compressor 21 Model number 22 Light All Segments 23 Activate Defrost Harvest press and hold for 3 seconds to activate defrost harvest 24 Defaults pres...

Страница 28: ...ent Mode on select models Clean Mode Hold the Clean button for 5 seconds to enter Clean mode on select models 1 Plug the unit into appropriate power source as defined on the data plate 2 Once the doub...

Страница 29: ...ts with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may be hear...

Страница 30: ...Purple Black Yellow Open Black White FUSE N C 11 22 1 10 1 1 5 1 6 1 4 12 Pump White light Bin temp Door switch Pump Low water sensor Water shutoff Dump Valve Resevoir Valve Auger Condenser Fan Open...

Страница 31: ...ring an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components REMOVE BASE ASSEMBLY 1 Disconnect power to...

Страница 32: ...ct waterline coming from inlet valve 9 Loosen hose clamp and disconnect ice transport tube remove hose clamp 10 Loosen hose clamp and disconnect drain tube remove hose clamp 11 Cut cable tie from wire...

Страница 33: ...Remove compression nozzle a Loosen hose clamp b Remove transport tube 6 Remove M6 socket head allen screw 7 Remove compression nozzle retainer 8 Remove compression nozzle 9 Remove main housing Disconn...

Страница 34: ...nstall auger 6 Install main housing a Slide main housing onto auger shaft b Install three M6x25 allen screws c Connect vent line to T fitting 7 Install compression nozzle Remove and inspect compressio...

Страница 35: ...spacer ensure that key is captured in slot 14 Insert screwdriver into groove of auger shaft and pry shaft outwards 15 Insert retainer into groove ensure that retainer is aligned with hole in spacer 16...

Страница 36: ...zed to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from t...

Страница 37: ...ing for warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update...

Страница 38: ...MBLY 80 55371 00 14 GASKET DOOR 80 55396 00 15 GRILLE ASSEMBLY 80 55373 00 16 HEAT EXCHANGER ASSEMBLY 80 55434 00 17 HINGE ASSEMBLY 80 55397 00 18 HINGE COVER 80 55499 00 19 ICE SCOOP 80 54080 00 20 L...

Страница 39: ...rovide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform you when the parts o...

Страница 40: ...cian must observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder t...

Страница 41: ...cuum pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the sys...

Страница 42: ...erant is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing...

Страница 43: ...Install a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two...

Страница 44: ...t Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room temperature due...

Страница 45: ...h are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefu...

Страница 46: ...please contact the U Line Corp Customer Care Facility at 1 800 779 2547 for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency...

Страница 47: ...cuit Unplug unit wait 5 seconds plug back in If main board does not beep check for 120V at black and white cables on power cord No Interior Light Light may be set to OFF Check LED strip for power Defe...

Страница 48: ...it to its factory default setting Factory defaults may be restored through the service menu If that does not work check that the board is programmed to the correct model in the service menu CAUTION Pr...

Страница 49: ...the display This mode can be canceled by pressing and releasing The mode will automatically be changed back to ON after three hours SHOWROOM MODE This mode is designed to show units in a display envir...

Страница 50: ...g Period frequency that data is output to diagnostics port 27 Factory test mode 0 Off 1 On 28 Compressor RPM 29 Freeze time adjust Model 54 only 30 Harvest time adjust Model 54 only 31 Low temp alarm...

Страница 51: ...operly 23 ACTIVATE DEFROST HARVEST Press and hold for 3 seconds to activate 24 FACTORY DEFAULTS Press and hold for 3 seconds to restore all values to factory defaults 25 MAIN SOFTWARE 26 Does not appl...

Страница 52: ...A 38 HWC524 1A 39 HWC524 2A 40 HWC336 1A 41 HBD324 1A 42 HBD324 2A 43 HBD524 1A 44 HBD524 2A 45 HWD324 2A 46 HWD324 1A 47 HWD524 2A 48 HWD524 1A 49 HRF124 2A 50 HRF124 1A 51 HRI124 2A 52 HRI124 1A 53...

Страница 53: ...Light 2 Evap Fan Cond Fan 22 RE336 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 23 RE515 1A Compressor Light 1 Light 2 Evap Fan Cond Fan 25 RE524 1A Compre...

Страница 54: ...ns Dielectric grease will help to keep thermistor connections clean and dry If you change a thermistor in the unit please re apply dielectric grease to the connection If you encounter a dirty thermist...

Страница 55: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: