background image

USER GUIDE

 Troubleshooting - Extended 2

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

REFRIGERATION SYSTEM DIAGNOSIS GUIDE

ERRORS

*All errors are logged in memory.
*Only door error is displayed on the display and has an
audible signal.
*For clear ice models, pump error is displayed via alert
light with no audible alerts.

E1:

Thermistor 1 open. Refrigerator Zone.

E2:

Thermistor 2 open. Evaporator.

E3:

Thermistor 3 open Freezer Zone.

E4:

Thermistor 4 open Ice Maker.

E5:

Thermistor 1 shorted. Refrigerator Zone.

E6:

Thermistor 2 shorted. Evaporator.

E7:

Thermistor 3 shorted.Freezer Evaporator.

E8:

Thermistor 4 shorted. Ice Maker

E9:

Door open error.

Pi:

Pump Circuit open (Does not apply to this model).

MAIN CONTROL

The main control board is very robust and is rarely the 
cause of system issues. It is important to fully diagnose 
the board for any suspected failures before attempting to 
remove the board for replacement or service. Follow the 
guidelines below to fully test and diagnose the main 
control.

Power Fault

If the unit does not (or seems to not) power on, follow the 
flow chart below to help diagnose the issue. Before 
beginning it is important to first verify the unit is not 
simply set to sabbath mode.

System 

Condition

Suction 

Pressure

Suction 

Line

Compressor 

Discharge

Condenser

Capillary 

Tube

Evaporator

Wattage

Normal

Normal

Slightly below 

room 

temperature

Very hot

Very hot

Warm

Cold

Normal

Overcharge

Higher than 

normal

Very cold -

may frost 

heavily

Slightly warm 

to hot

Hot to warm

Cool

Cold

Higher than 

normal

Undercharge

Lower than 

normal

Warm -

near room 

temperature

Hot

Warm

Warm

Extremely cold 

near inlet - 

outlet below 

room 

temperature

Lower than 

normal

Partial 

Restriction

Somewhat 

lower than 

normal -

in vacuum

Warm - 

near room 

temperature

Very  hot

Top passes warm 

lower passes 

cool (near room 

temperature due 

to liquid

Room 

temperature 

(cool) or colder

Extremely cold 

near inlet -

outlet below 

room 

temperature 

backing up

Lower than 

normal

Complete 

Restriction

In deep 

vacuum

Room 

temperature 

(cool)

Room 

temperature 

(cool)

Room 

temperature 

(cool)

Room 

temperature 

(cool)

No refrigeration Lower than 

normal

No Gas

0 PSIG to 25"

Room 

temperature 

(cool)

Cool to hot

Room 

temperature 

(cool)

Room 

temperature 

(cool)

No refrigeration Lower than 

normal

41

Содержание U-CO1224FB-00B

Страница 1: ...USER GUIDE SERVICE MANUAL Model U CO1224FB 00B...

Страница 2: ...on Grille Plinth Installation Door Swing Door Adjust Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Ice Sabbath Mode Airf...

Страница 3: ...ldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Produ...

Страница 4: ...hroughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow this saf...

Страница 5: ...r take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations re...

Страница 6: ...and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct s...

Страница 7: ...e unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has bee...

Страница 8: ...t in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAUTION Un...

Страница 9: ...Product Dimensions 1 SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 24 610 mm 3 9 16 91 mm Not Including Handle 23 1 4...

Страница 10: ...ording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown belo...

Страница 11: ...t off valve in the supply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged dur...

Страница 12: ...e water valve inlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on wate...

Страница 13: ...s only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screw...

Страница 14: ...otal unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjus...

Страница 15: ...ing the grille When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the gri...

Страница 16: ...cent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance if ins...

Страница 17: ...TO ALIGN AND ADJUST THE DOOR Remove grille Remove the grille see GRILLE PLINTH INSTALLATION section of this guide 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet...

Страница 18: ...oor for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws holding th...

Страница 19: ...unit is not installed in surrounding cabinetry Available at u line com To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet...

Страница 20: ...ernight before loading with product U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line...

Страница 21: ...CTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and be...

Страница 22: ...ounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp instrument...

Страница 23: ...Remove the ice maker assembly cover 1 2 Find the adjusting screw on the ice maker assembly control box 2 The adjusting screw is just below the minus and plus signs on the control box CAUTION Too larg...

Страница 24: ...abbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will flash briefly at the end of the ten second period 2 The interior light and control display 3 will go dark until user rese...

Страница 25: ...rm at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporator and...

Страница 26: ...lling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place the sh...

Страница 27: ...e and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with...

Страница 28: ...njury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or other a...

Страница 29: ...nditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins are SHAR...

Страница 30: ...ines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures o...

Страница 31: ...components listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser...

Страница 32: ...door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Obstruction of front grille or condenser Digital Display Shows 1 16 or 99 A factory test mo...

Страница 33: ...BLACK RED BROWN WHITE BROWN ORANGE ORANGE ORANGE BLACK BLACK BLACK BLACK BLACK GREEN W YELLOW BLACK YELLOW RED PURPLE WHITE WHITE WHITE WHITE LIGHT BLUE TO COMPRESSOR WHITE WHITE ORANGE PURPLE WHITE...

Страница 34: ...a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of...

Страница 35: ...12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may submitt...

Страница 36: ...ge assembly 80 54307 00 20 Gasket door 80 54213 00 21 Glass shelf 1 btm 80 54274 00 22 Glass shelf 1 top 80 54304 00 23 Grille w screws 80 54267 00 24 Handle w logo 80 54214 00 25 Hinges 2 w screws 80...

Страница 37: ...l be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line r...

Страница 38: ...r than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room te...

Страница 39: ...ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run winding resistan...

Страница 40: ...clean Confirm condenser fan operation Confirm proper compressor operating voltage Use 19 Component Testing in Service Mode Compressor not operating Confirm proper compressor operating voltage Use 19 C...

Страница 41: ...unit does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode System Condit...

Страница 42: ...have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to its fact...

Страница 43: ...normally Evaporator thermistor errors will be displayed in the error log Always assure that all thermistor connections are clean and dry Whenever opening a thermistor connection be sure to apply a fre...

Страница 44: ...through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates light for 3...

Страница 45: ...xit this mode hold the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow t...

Страница 46: ...OR 4 SET POINT MINUS OFFSET This shows the thermistor reading with offsets taken into account 12 ADJUST DEFROST INTERVAL 3 TO 24 HOURS This will adjust the interval between defrosts from 3 to 24 hours...

Страница 47: ...me in minutes the fan will be delayed from starting from the beginning of a cooling cycle Adjustable 0 99 minutes 18 EVAPORATOR FAN DELAY IN MINUTES OFF Fan Delay Off is the amount of time in minutes...

Страница 48: ...nit into the appropriate power source 4 When the flashing digits appear 3 5 seconds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb...

Страница 49: ...an Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC N A N...

Страница 50: ...e Control Operations Service section This unit has three thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature within that zone Thermi...

Страница 51: ...24 RF 12 45 15 9 1215 1224 2218 2245 2224 2260 WC ZWC 12 45 45 7 1215 1224 2218 2245 2224 2260 R RSOD RDC BEV DC DWR RGL 12 45 42 6 CO29 F 12 18 n a CO1224 F 12 18 45 7 1224FZR Freezer Mode 6 45 42 6...

Страница 52: ...R 1 Disconnect unit from power source 2 Remove two screws from fan cover 3 Remove two screws holding fan bracket to liner 4 Unplug fan connection 5 Remove two nuts holding the fan to the fan bracket 6...

Страница 53: ...ected 2 Disconnect ice maker wire harness at plug 3 Disconnect thermistor plug 4 Remove water inlet tube 5 Remove three screws from wall of freezer housing 6 Remove ice maker assembly INSTALL ICE MAKE...

Страница 54: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Отзывы: