![U-Line U-CLR1215SOD-00A Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/u-line/u-clr1215sod-00a/u-clr1215sod-00a_user-manual-and-service-manual_4484324046.webp)
USER GUIDE
Control Operation - Service 2
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
CONTROL QUICK GUIDE
ELECTRONIC CONTROL DESCRIPTIONS
Except as noted, these functions are available on all
models.
1.
ON/OFF
The ON/OFF mode allows the unit to be turned on and
off via the keypad. Push/release power key to toggle
ON/OFF. Internal lights will go off with power.
NOTICE
This does not apply to ADA24R glass door units.
The light and display are always off when the
glass door is closed.
2.
VIEWING BIN THERMISTOR SET POINT
To view the set point temperature at which the bin
thermistor will stop ice production, push and release
the up and down arrow icons. Adjustments to this can
be made in the service mode.
3.
CHANGING FROM FAHRENHEIT TO
CELSIUS
To change the displayed temperature from °F to °C,
hold the up and down arrows for 5 seconds. Repeat to
change back.
4.
SHOWROOM MODE
This mode is designed to show units in a display
environment. When in this mode the only functions will
be the control and cabinet lights. The compressor,
fans, etc. will not operate. To enter this mode, hold
the light key and the power key for 5 seconds. The
display will flash once and beep and the degree symbol
will begin to flash. When the degree symbol is flashing
the unit will allow the use of the control for
demonstrations. The unit can be left in this mode
indefinitely. To exit this mode, interrupt power to the
unit.
5.
SERVICE MODE
This mode has 28 different options available for service
diagnostics. To enter the mode hold the hidden key for
10 seconds. The display will show “0.” When in this
mode use the up and down arrows to select the desired
option. The LIGHT key is the ENTER key and will enter
a function. If changing a setting, you must press the
LIGHT key again to retain the changed setting. To exit
the service mode scroll to option “0” and press the
LIGHT key. After five minutes of not touching any keys
the mode will also exit automatically.
CONTROL FUNCTION GUIDE
FUNCTION
COMMAND
DISPLAY/OPTIONS
ON/OFF
Push and release the power key to power the unit
ON or OFF
View bin thermistor set
point
Push and release the UP and DOWN icons, the bin
thermistor set point will display
Toggle display, F/C
Push and hold the UP and DOWN icons for 5
seconds. Repeat to change back.
Turn on showroom mode
Hold light and power key for 5 seconds to turn on
showroom mode. To exit showroom mode, interrupt
power to the unit.
Service mode
Push and hold the hidden icon for ten seconds, use
the arrow icons to scroll through the service menu
Silent mode
Hold the power and down arrow icon for 5 seconds,
the unit will shut down for 3 hours. Repeat the
prompt to exit.
Clean cycle
Push and hold the clean icon for 5 seconds
Ice thickness adjust
Hold the up arrow icon for 5 seconds
46