Electrical

WARNING

!

SHOCK HAZARD — Electrical Grounding 
Required. Never attempt to repair or perform 
maintenance on the unit until the electricity has 
been disconnected.

Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.

Altering, cutting or removing power cord, 
removing power plug, or direct wiring can cause 
serious injury, fire, loss of property and/or life, 
and will void the warranty.

Never use an extension cord to connect power to 
the unit.

Always keep your working area dry.

NOTICE

Electrical installation must observe all state and 
local codes. This unit requires connection to a 
grounded (three-prong), polarized receptacle 
that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A power supply (normal household current). An 
individual, properly grounded branch circuit or circuit 
breaker is recommended. A GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
it could be prone to nuisance tripping. However, be sure 
to consult your local codes.

Door Swing

Units have a zero clearance for the door to open 90°, 
when installed adjacent to cabinets. 

Stainless Steel and black and white models require 2-1/8" 
(54 mm) door clearance to accommodate the handle if 
installed next to a wall. 

Integrated models require 1/4" (6 mm) clearance if 
installed next to a wall. Allow for additional space for any 
knobs or pulls installed on the integrated panel/frame.

Wall

Wall

90°

Door Swing

90°

Door Swing

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

3

Содержание U-ADA24RINT-00A

Страница 1: ...QUICK START GUIDE 1000 Series 115 V 60 Hz...

Страница 2: ...continents for over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Complian...

Страница 3: ...t no charge when you register your product on u line com See complete warranty for details Contents 1 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Door Swing 4 Door Adjustments 8 Gen...

Страница 4: ...ury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage DANGER This unit contains R600a Isobutane w...

Страница 5: ...may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops CAUTION Damages caused by ambient temperatures of 40 F 4 C or below are not covered by...

Страница 6: ...acle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit o...

Страница 7: ...r 1 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 2 Align door squarely with cabinet 3 Make sure gasket is firmly in contact...

Страница 8: ...nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to only remove the...

Страница 9: ...gasket is firmly in contact with cabinet all the way around the door no gaps 4 Tighten bottom hinge screws 5 Tighten top hinge screws REVERSING THE DOOR Location of the unit may make it desirable to m...

Страница 10: ...door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws holding t...

Страница 11: ...e a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Re...

Страница 12: ...construction or surrounding cabinetry the panel may not sit flush with the top of the door drawer 9 Secure integrated panel to door drawer using clamps A robust tape may also be used U Line recommend...

Страница 13: ...channel 14 Remove clamps from door drawer If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 15 Star...

Страница 14: ...C Hold and for 5 seconds The display will change units Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will...

Страница 15: ...will beep and display will show the default set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interio...

Страница 16: ...e This set point temperature is a base setting used by the controller to maintain the temperature zone in the unit The factory default MID setting number 4 set point is approximately 38 F 3 C The set...

Страница 17: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Отзывы: