Water Hookup

FRONT MOUNTED VALVE

PREPARE PLUMBING

Please use a braided stainless steel water supply line. 
P/N (WATERHOOKUP).

CAUTION

!

Plumbing installation must observe all state and 
local codes. All water and drain connections 
MUST BE made by a licensed/qualified plumbing 
contractor. Failure to follow recommendations 
and instructions may result in damage and/or 
harm.

Water Supply Connection

When connecting the water supply, please note the 
following:

• Before installing the unit and connecting to the cold 

water supply, review the local plumbing codes.

• The water pressure should be between 20 and 120 psi.

• The water line MUST have a shut-off valve in the 

supply line.

• The water line should be looped into 2 coils. This will 

allow the unit to be removed for cleaning and servicing. 
However, make certain that the tubing is not pinched 
or damaged during installation.

CAUTION

!

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use Teflon tape or joint compound on the 
water fitting. The rubber washer provides an 
adequate seal. Other materials could cause 
blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

CAUTION

!

Turn off water supply and disconnect electrical 
supply to unit prior to installation.

Use caution when handling back panel. The 
edges could be sharp.

1. Turn off water supply and disconnect electrical supply 

to product prior to attempting installation.

2. Remove the grille/access panel in the front and the 

back panel.

3. Locate water 

valve in the front 
of the unit and 
thread water 
supply line 
through.

NOTICE

Route the water 
supply line 
through the unit 
so it does not come into contact with any 
internal components other than the solenoid 
valve. Normal operation creates some vibration. 
A water supply line contacting an internal 
component or cabinet wall can cause excessive 
noise during operation or damage to the line.

Содержание U-ADA15IMB-00A

Страница 1: ...QUICK START GUIDE Ice Makers 115 V 60 Hz ...

Страница 2: ...ODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Integrated Panel Instructions Compliance Documentation and Product Warranty information are all available for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U...

Страница 3: ...QUICK START GUIDE u line com Contents 1 Model List 3 Safety and Warning 3 Environmental Requirements 4 Water Hookup 7 Door Swing 7 General Installation 8 First Use 8 Ice 9 Warranty ...

Страница 4: ...ooking for more information Visit u line com to view detailed User Guides for all U Line products Crescent Ice Makers U BI1215S 00A U BI1215INT 00A U BI1215B 00A U BI1215W 00A ADA Series U BI95B 00A U BI95W 00A U BI98B 00A U BI98W 00A U ADA15IMS 00A U ADA15IMB 00A Outdoor Series U BI1215SOD 00A ...

Страница 5: ...03A ULN SS1095FC 20A ULN SS1095FD 03A ULN SS1095FD 20A ULN SS1095NF 03A ULN SS1095NF 20A ULN SP18FCS 03A ULN SP18FCS 20A ULN SP18FCB 03A ULN SP18FCB 20A ULN SP18FCW 03A ULN SP18FCW 20A ULN SS98NF 03A ULN SS98NF 20A Visit http www u line com product literature userguides or scan this QR code to view all user guides online ...

Страница 6: ...in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage Environmental Requirements This unit is designed to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable ...

Страница 7: ... supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use Teflon tape or joint compound on the water fitting The rubber washer provides an adequate seal Other materials could cause blockage of the valve Failure to follow recommendations and instructions may result in damage and or harm flooding or void the product warranty C...

Страница 8: ...ailure to follow recommendations and instructions may result in damage and or harm Water Supply Connection When connecting the water supply please note the following Before installing the unit and connecting to the cold water supply review the local plumbing codes The water pressure should be between 20 and 120 psi The water line MUST have a shut off valve in the supply line The water line should ...

Страница 9: ...nect electrical supply to unit prior to installation Use caution when handling back panel The edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Locate water valve inlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water ...

Страница 10: ... 4 6 mm to accommodate the handle if the unit is installed next to a wall MARINE SERIES All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 3 4 19 mm to accommodate the handle if the unit is installed next to a wall or similar type of structure General Installation MARINE AND BI SERIES LEVELING INFORMATION NOTICE It is extremely important that thes...

Страница 11: ...e in the main water source 2 Plug in the power cord 3 Gently push the unit into position Be careful not to kink the water supply line or entangle the power cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop First Use All U Line controls are preset at the factory Initial startup...

Страница 12: ...s in materials and workmanship for a period of one year two years on Modular 3000 Series from the date of purchase U Line further warrants the sealed system consisting of the compressor condenser evaporator hot gas bypass valve dryer and connecting tube in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase 2 During the init...

Страница 13: ...s website and or on the serial tag located inside the product A Outdoor product may come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from a hose or similar device into and arou...

Отзывы: