QUICK START GUIDE

u-line.com

QUICK START GUIDE

8

u-line.com

General Installation

LEVELING INFORMATION

1. Use a level to 

confirm the unit is 
level. Level should 
be placed along top 
edge and side edge 
as shown.

2. If the unit is not level, adjust the legs on the corners of 

the unit as necessary.

3. Confirm the unit is level after each adjustment and 

repeat the previous steps until the unit is level.

INSTALLATION TIP

If the room floor is higher than the floor in the cutout 
opening, adjust the rear legs to achieve a total unit rear 
height of 1/8" (3 mm) less than the opening’s rear height. 
Shorten the unit height in the front by adjusting the front 
legs. This allows the unit to be gently tipped into the 
opening. Readjust the front legs to level the unit after it is 
correctly positioned in the opening.

INSTALLATION

1. Plug in the power/electrical cord.

2. Gently push the unit into position. Be careful not to 

entangle the cord.

3. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" (3 mm) below 
the countertop.

4. Remove the interior packing material and wipe out the 

inside of the unit with a clean, water-dampened cloth.

1

Turn to Adjust

8

Содержание U-29RW-15A

Страница 1: ...QUICK START GUIDE 1000 Series 115 V 60 Hz...

Страница 2: ...cades and is proud to have the opportunity to ship to you U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec She...

Страница 3: ...t no charge when you register your product on u line com See complete warranty for details Contents 1 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Door Swing 4 Door Adjustments 8 Gen...

Страница 4: ...ury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage DANGER This unit contains R600a Isobutane w...

Страница 5: ...may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops CAUTION Damages caused by ambient temperatures of 40 F 4 C or below are not covered by...

Страница 6: ...acle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit o...

Страница 7: ...r 1 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 2 Align door squarely with cabinet 3 Make sure gasket is firmly in contact...

Страница 8: ...nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to only remove the...

Страница 9: ...gasket is firmly in contact with cabinet all the way around the door no gaps 4 Tighten bottom hinge screws 5 Tighten top hinge screws REVERSING THE DOOR Location of the unit may make it desirable to m...

Страница 10: ...door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws holding t...

Страница 11: ...e a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Re...

Страница 12: ...construction or surrounding cabinetry the panel may not sit flush with the top of the door drawer 9 Secure integrated panel to door drawer using clamps A robust tape may also be used U Line recommend...

Страница 13: ...channel 14 Remove clamps from door drawer If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 15 Star...

Страница 14: ...ll change units Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so until user resets...

Страница 15: ...ep and display will show the default set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light...

Страница 16: ...e This set point temperature is a base setting used by the controller to maintain the temperature zone in the unit The factory default MID setting number 4 set point is approximately 38 F 3 C The set...

Страница 17: ...lood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that...

Отзывы: