Product Liability

Field service technicians are authorized to make an initial 
assessment in the event of reported damages. If there are 
any questions about the process involved, the technician 
should call U-Line for further explanation.

While inspecting for defects or installation issues, photos 
should be taken to document any damages or issues 
found.

During the assessment, if the service technician is able to 
find the source of the damage and it can be resolved by 
replacement of a part, the servicer is authorized to 
replace the part in question. The part that caused the 
damage must be returned to U-Line in its entirety. The 
part must be clearly labeled with the serial number of the 
unit it was removed from, the date, and the servicer who 
removed the part. 

If the service technician determines the damage is the 
result of installation issues (water connection/drain, etc.), 
the consumer would be notified and the issues shall be 
resolved at the direction of the consumer.

If damage is evident and the service technician is unable 
to find the source, U-Line must be contacted at 1-800-
799-2547 for further direction

8900 N. 55th Street • Milwaukee, WI 53223

T: +1.414.354.0300 • F: +1.414.354.354.5696

Website: 

www.u-line.com

Right product. Right place. 

Right temperature Since 1962.

36

Содержание U-1024BEVS-00B

Страница 1: ...USER GUIDE SERVICE MANUAL Model U 1024BEVS 00B...

Страница 2: ...tallation Grille Plinth Installation Door Swing Door Adjust Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Airflow and Product Loading U Li...

Страница 3: ...ldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Produ...

Страница 4: ...r death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may resul...

Страница 5: ...r take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations re...

Страница 6: ...and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct s...

Страница 7: ...e unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has bee...

Страница 8: ...en built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAU...

Страница 9: ...Product Dimensions 1 SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 24 610 mm 3 9 16 91 mm Not Including Handle 23 1 4...

Страница 10: ...ording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown belo...

Страница 11: ...s only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screw...

Страница 12: ...the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently ti...

Страница 13: ...NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Remove control knob 3 3 Loosen the screw 1 in the center 4 Remo...

Страница 14: ...cent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance if ins...

Страница 15: ...TO ALIGN AND ADJUST THE DOOR Remove grille Remove the grille see GRILLE PLINTH INSTALLATION section of this guide 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet...

Страница 16: ...oor for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws holding th...

Страница 17: ...open past 90 do not require this step 1 Remove wine rack see WINE RACK INSTALLATION in Maintenance 2 Starting from the side that has the spacers previously unaltered units will be on the right hand si...

Страница 18: ...unit is not installed in surrounding cabinetry Available at u line com To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet...

Страница 19: ...ends allowing the unit to run overnight before loading with product MECHANICAL DIAL CONTROL The control dial turns unit ON OFF and sets temperature This set point temperature is a base setting used by...

Страница 20: ...st efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporator and product loaded...

Страница 21: ...ect of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and Wine Al...

Страница 22: ...entation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurateurs wou...

Страница 23: ...iment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine bottle...

Страница 24: ...U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable storag...

Страница 25: ...age Specially designed horizontal wine racks properly position the bottles so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bott...

Страница 26: ...pen door completely 2 Grasp the shelf edge in the center and slide the shelf from the unit Insert the shelves as follows 1 With the door still fully opened reposition the shelf as required ensure the...

Страница 27: ...e and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with...

Страница 28: ...njury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or other a...

Страница 29: ...ry Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser...

Страница 30: ...me lift the matching right rack release lever up Pull the rack out until it is free of the tracks and the cabinet NOTICE Do not remove the track rails from the cabinet To insert rack in the cabinet 1...

Страница 31: ...interior and will compromise the precise temperature control of the unit 1 Find the light located at the top of the unit Grasp the edges of the light housing lens 1 opposite the exposed tab and gentl...

Страница 32: ...returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to pr...

Страница 33: ...on components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that...

Страница 34: ...setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illuminated...

Страница 35: ...Diagram 42342_A WIRING DIAGRAM GROUND GREEN or GREEN W YELLOW NEUTRAL HOT RELAY EMBRACO COMPRESSOR GREEN or GREEN W YELLOW GROUND 115 VOLT PLUG 220 240 VOLT PLUG OVERLOAD CAP CONTROL DOOR SWITCH LIGH...

Страница 36: ...a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of...

Страница 37: ...12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may submitt...

Страница 38: ...pan w double sided tape 80 54217 00 12 Drier 80 54055 00 13 Evaporator assembly 80 54211 00 14 Glass shelf 1 w edge trim 80 54220 00 15 Grille w screws 80 54207 00 16 Handle w logo 80 54214 00 17 Hing...

Страница 39: ...l be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line r...

Страница 40: ...r than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room te...

Страница 41: ...strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S p...

Страница 42: ...or perform maintenance on the unit until the main electrical power has been disconnected from the unit TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify p...

Страница 43: ...or The pressure of the refrigerant is reduced to the evaporating or low side pressure The reduction of pressure on the liquid refrigerant causes it to boil or vaporize until it reaches saturation temp...

Страница 44: ...IDE Defrost 1 Defrost These units are automatic cycle defrost unit will defrost itself when the control sensor is satisfied of internal temperatures Defrost mode ends when control sensor asks for cool...

Страница 45: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...