MAINTENANCE CONTINUED

REPLACING A WORN BELT

WARNING! Belt pulleys can become hot during 
normal use. To prevent burns, avoid touching 
the belt pulley when servicing the drive belt.

1.  Release cam locks (1) and remove bottom plate. 

Pull up on belt to rotate it off motor pulley. Lift up 

on brush roll and remove worn belt. Place new belt 

around the brush roll. Align brush roll belt (3) with  

belt guide. (See Figure 13)

2.  Ensure rubber end cap cover (2) is installed  

correctly. Align end caps with slots in vacuum base. 

Push brush roll into base. (See Figure 13)

3.  Place lower side of belt into belt guide and pull to 

stretch the belt around the left side of the motor 

pulley. Rotate pulley to secure the belt into the 

groove. Replace bottom plate and secure with  

cam locks. (See Figure 13)

ove

lley

s

Belt g

Bottom 

Metal Plate

Bottom 

Metal Plate

Rubber End 

Cap Cover

Motor Pulley

Belt Groove

Belt Guide

Brush Roll 

Belt

Brush Roll

1

2

3

Figure 13

REPLACING BRISTLE STRIPS

1.  Remove rubber end cap cover (A) from one end. 

Unscrew locknut (B). Remove end cap (C) – sleeve 

bearing brush roll includes a shaft washer not shown.  

(See Figure 14)

2.  Remove bearing retainer (D). Push shaft (E) through 

opposite end. Pull out worn bristle strip (F) with pliers. 

Slide in new bristle strip of same length (rounded 

end first). (See Figure 14)

A

B

C

D

F

E

5

A

B

E

F

Figure 14

1

2

A

B

C

D

F

E

3.  Fit track on either side of the bristle strip into the 

brush roll slot. Replace the second strip from 

opposite end of brush roll.

4.  Replace shaft. Align indentation on bearing 

retainer with bristle strip on both ends of brush roll. 

Reassemble the remainder of brush roll and secure 

into the base.

CAUTION! Turn off the switch and unplug the 
electrical cord before maintenance.

IMPORTANT! Improper installation of the brush 
roll or brush roll belt could cause carpet or 
vacuum damage.

Содержание SANITAIRE H-10152

Страница 1: ...ith wet hands Do not put any object into openings Do not use with any opening blocked Keep openings free of dust lint hair or anything that may reduce airflow Keep hair loose clothing fingers and all...

Страница 2: ...cord for this vacuum has an equipment grounding conductor and a grounding plug It must only be plugged into an outlet that is properly installed and grounded in accordance with all local codes and or...

Страница 3: ...r low furniture HEIGHT SETTINGS WARNING To prevent injury keep loose clothing hair fingers and all other parts of body away from any moving part such as the revolving brush Turn cleaner off and unplug...

Страница 4: ...op of the dirt tube and pull the dust bag collar forward See Figure 9 4 Place new dust bag collar on the tabs of the dirt tube interface Rotate up until dirt tube tabs fasten into holes in dust bag co...

Страница 5: ...Metal Plate Bottom Metal Plate Rubber End Cap Cover Motor Pulley Belt Groove Belt Guide Brush Roll Belt Brush Roll 1 2 3 Figure 13 REPLACING BRISTLE STRIPS 1 Remove rubber end cap cover A from one end...

Страница 6: ...1 If a clog is not around the brush roll there may be a clog in the clear fan chamber If you see a clog release two cam locks and remove bottom plate See Figure 15 Remove the two screws to release th...

Страница 7: ...s clogged Remove bottom metal plate Check for clog in base and or brush roll Remove dust bag Check for clog where dust bag attaches to dust bag collar and where the dust bag attaches to the dirt tube...

Отзывы: