U-Line RUG DOCTOR H-10972 Скачать руководство пользователя страница 4

PAGE 4 OF 9 

1123 IH-10972

SAFETY CONTINUED

OPERATION

•  Do not put bleach, dye or products other than 

Rug Doctor

®

 cleaners in this machine. Use of 

inappropriate products may cause this machine to 
malfunction and may result in carpet or machine 

damage. 

•  Foam should never be ingested through the dome 

filter. Damage to the carpet and/or vacuum motor 

could result. 

•  To reduce the risk of fire and electric shock due  

to internal component damage, use only  
Rug Doctor

®

 cleaning products intended for use 

with this appliance. 

•  Avoid picking up hard or sharp objects, as they 

may damage the machine. Do not use the 
machine for dry vacuuming because this machine 

does not have a fine dust filter. Dry vacuuming 
damages the vacuum motor. 

•  Do not use the machine to vacuum large 

quantities of liquid, such as a flooded basement or 

large spills. This machine is not equipped with an 
automatic overflow shutoff. 

•  To avoid damage, do not place the machine or 

hand tool on hardwood or laminate flooring. Do 
not allow any solution or overspray to contact such 
flooring. 

•  To avoid pump damage, do not continue to press 

the spray (pump) switch when the solution tank is 
empty. 

•  Read instructions carefully. Both Rug Doctor

®

 and 

Uline are not responsible for damage due to 
misuse of this machine.

CARPET CLEANING 

NOTE: Machine is designed to deep clean and 

extract in one cleaning pass. For best results, 

use only Rug Doctor

®

's cleaning products. 

CAUTION! Avoid over-wetting carpet. Do not 
go over a heavily-soiled spot more than two 

times. Berber, multi-level or looped carpets 
retain more liquid. For these types of carpets, 

do not repeat cleaning passes. If additional 
cleaning is desired, allow carpets to dry 

before attempting to reclean heavily-soiled 

areas. Because they retain more liquid, berber 
carpets that are over-wet can experience  

 "wick up" of soils or spills very deeply 

embedded in the carpet or backing. If 
experiencing this problem, allow area to dry 
completely then clean again using single, 
quick passes (1-2 feet per second). 

CLEANING BERBER CARPET

NOTE: For best results, make only one pass 
while depressing the thumb switch to release 
solution. Make a second pass over the same 
area without pressing the switch so that user is 

only vacuuming the liquid. Ensure the vacuum 
slot at the front bottom edge of the machine is 
snug against the carpet. 

•  Overlap passes slightly to cover all areas.

IMPORTANT! When pressing the red button, 
keep machine moving so vibrating brush does 
not agitate in one place. 

LIQUID RECOVERY

•  User should recover 70-80% of the liquid used 

depending on your carpet type. With berber carpet, 

a little less liquid may be recovered. 

•  Avoid excessive foam in the recovery tank, which 

can be expelled through the machine and may 

affect carpet. If foaming occurs, turn off the 

machine and empty the upper white tank if it is full. 

•  If replacing furniture before the carpet is completely 

dry, place aluminum foil under furniture legs to 

prevent stains. Leave aluminum foil under furniture 

legs until carpet is completely dry. 

•  For faster drying, ventilate area. Open doors and 

windows. Place fans pointed downward on carpet. 

Turn on heat in damp or cold weather. Turn on air 

conditioner in humid or hot weather. This is highly 

recommended when cleaning berber carpets.

Содержание RUG DOCTOR H-10972

Страница 1: ...clude permanent staining of carpet Use caution when using hot tap water Do not boil or microwave water to be used in this machine Do not allow the machine to run dry When the solution tank runs out st...

Страница 2: ...reproductive harm Connect to properly grounded outlet only See Grounding Instructions on page 3 WARNING Machine may contain water For best cleaning results and to avoid the risk of permanent damage to...

Страница 3: ...to chemicals including Diethylhexyl Phthalate DEHP lead and other chemicals known to the state of California to cause cancer birth defects or possible reproductive harm For a complete list of warning...

Страница 4: ...looped carpets retain more liquid For these types of carpets do not repeat cleaning passes If additional cleaning is desired allow carpets to dry before attempting to reclean heavily soiled areas Bec...

Страница 5: ...tor Oxy Cleaning solution by pouring through the white filter screen Machine is full when liquid halfway covers the filter screen See Figure 5 5 Replace recovery tank and close the dome hood 6 Plug in...

Страница 6: ...hly vacuuming or brushing When cleaning and drying cushions first spread sheets or towels on the floor as a drying surface for the dampened cushions 2 Disconnect the large vacuum hose Reconnect the to...

Страница 7: ...h Section After each use unplug the machine from power source and use your finger or an old comb to remove any debris from the vibrating brush If you used any Rug Doctor attachments also remove debris...

Страница 8: ...s lost vacuum pressure Ensure the dome hood is closed and securely sealed Check the hose connection at the back of the machine and secure if necessary Clean the filter that is in the dome Remove any a...

Страница 9: ...e tip and blow air through it to remove any build up that may be clogging the tip Reattach the tip with the nut driver Ensure to position the tip opening so that it sprays side to side Check the lower...

Отзывы: