The following procedure is designed to provide a finished, 
handleless frame for a 24" (600 mm) door that seamlessly 
integrates with its surrounding cabinetry.

NOTE: Many cabinet manufacturers provide a ready 
solution for a handleless, integrated design that can be 
easily applied to your U-Line 3000 Series model. Consult 
your cabinet manufacturer for applicable design and 
installation details. The cabinet manufacturer’s solution to 
this design and integration detail will often result in an 
integrated frame solution wherein the size of the frame 
may result in a height dimension taller than what we 
specify. This can be achieved provided the additional 
height is positioned above the appliance door.

NOTICE

The integrated frame aligns with the 
surrounding cabinetry and, due to differences in 
cabinetry, may not align perfectly with the door.

The appliance will need up to 34-1/2" (876 mm) 
to the underside of the counter to leave room for 
leveling adjustments.

A single prepared frame with insert must not 
weigh more than 20 lbs (10 kg).

Integrated Frame Preparation

1. Cut the main panel to the appropriate dimensions 

below. For details, see the drawings on the next page.

2. Create the top design for the handleless feature and 

the 1/8" (3 mm) notch for the insert(s) indicated on the 
Top Detail drawing, on the next page.

3. Prepare the insert(s) that will back up the handleless 

design. 

Wooden Insert

 – Cut 1/8" (3 mm) thick 

wooden insert(s) to the dimensions below.

4. Optional: Stain or finish frame and wooden insert to 

desired stain or color. Be sure to closely follow the 
instructions provided by the manufacturer.

NOTICE

If finishing panel or wooden insert, all sides 
must be finished to prevent warping.

5. Attach the insert to the frame. Wood glue or equivalent 

adhesive should be used to attach insert to frame.

Main panel width

Main panel depth

23-1/2" (595 mm)

28-13/16" (732 mm)

Wooden insert width

Wooden insert depth

23-1/2" (595 mm)

3-1/2" (89 mm)

Cutout

Integrated Frame

Main Panel

Wooden Insert

Top Design
and Insert Notch

Attach Wooden Insert

5

Содержание Modular 3024RGL

Страница 1: ...GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3024RGL 24 Glass Door Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE...

Страница 2: ...USER GUIDE SERVICE MANUAL u line com Table of Contents Installation Integrated Panel Dimensions Integrated Panel Installation Integrated Grille Dimensions Grille Plinth Installation...

Страница 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Страница 4: ...0 lbs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed...

Страница 5: ...door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared frame with insert must not weigh more than 20 lbs 10 kg Integ...

Страница 6: ...RVICE Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Cutout for F...

Страница 7: ...dimensions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optio...

Страница 8: ...ed Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integra...

Страница 9: ...integrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY FRAME FLAT AND WITHOUT INTERFERENCE...

Страница 10: ...stain your grille plinth strip base fascia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish appli...

Страница 11: ...e will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to...

Страница 12: ...strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fasc...

Отзывы: