U-Line H-5814 Скачать руководство пользователя страница 8

PAGE 8 OF 8 

0216 IH-5814

ROUTINE MAINTENANCE

DAILY

1. 

Filter

 - Check cartridge filter for clogs or heavy 

soiling and replace if necessary. Ensure that correct 

filters are being used for the task – see Filters section 

of instruction manual. 

2. 

Collection Bag

 - If using collection filter bag, check 

to ensure that there are no rips or tears in the bag 

and that the bag is not full.

3. 

Tank

 – If vacuuming up wet or damp material, 

empty the tank after use, as musty odors may occur 

if debris is left inside.

4. 

Extension Cord and Plug

 – Check extension cord 

and plug for any cuts or damage. If damaged, 

replace motor housing unit.

5. 

Motor 

– If there are unusual sounds or if poor 

performance occurs, the motor should be inspected 

immediately. Contact Uline Customer Service.

WEEKLY

1. 

Wands/Tools

 – Inspect wands and tool attachments 

for any damage. Replace if necessary.

2. 

Hose

 – Inspect hose for any damage and replace if 

necessary.

MONTHLY

1. 

Cleaning

 – Inspect and clean all areas of the 

vacuum, including the inside of the tank. 

TROUBLESHOOTING

ISSUE

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Parts/accessories missing

1.  Packed in tank

1.  Check in tank

Vacuum cleaner will not start

1. 

No power at receptacle

2.  Defective switch

3.  Defective motor

1.  Check for power

2.  Replace switch

3.  Replace motor

Dust discharging from exhaust

1. 

Filter not installed or installed improperly

2.  Filter damaged

3.  Filter clogged or dust is too fine

4. 

Filter not functional

1.  Properly install filter

2.  Replace filter

3.  Use more efficient filter

4.  Clean and replace filter

Loss of suction

1. 

Loose hose connection

2.  Filter clogged

3.  Full tank

4.  Hole in hose

1.  Tighten hose connection

2.  Clean or replace filter

3.  Empty tank

4.  Replace hose

Static shock

1. 

Dry environment 

2.  Relative humidity of air is low

1.  Add moisture to air (if practical, use a 

console or installed humidifier)

2.  This situation is temporary and does not 

affect the use of the vacuum cleaner

π

  CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

1-800-295-5510

uline.com

Содержание H-5814

Страница 1: ...ot Pull or carry by cord use cord as a handle close a door on cord pull cord around sharp edges or corners or run appliance over cord 7 Keep cord away from heated surfaces 8 Do not unplug by pulling o...

Страница 2: ...by the Canadian Electrical Code Make sure that the appliance is connected to an outlet having the same configuration as the plug No adapter should be used with this appliance EXTENSION CORDS When usi...

Страница 3: ...ure the correct filters are installed for your cleaning operation 2 Replace tank cover Make sure each latch or clamp is secured over the raised area of the tank cover Failure to properly secure the la...

Страница 4: ...or add a disposable filter bag to maintain maximum pickup power DRY PICKUP OPERATION NOTE Never use the vacuum for dry pickup without a dry use filter installed Using the vacuum without a filter will...

Страница 5: ...onnected from the receptacle tank cover is removed and the hose is disconnected from tank inlet 2 Remove inlet deflector from deflector guide NOTE Hose must be removed before inlet deflector can be ta...

Страница 6: ...located on the back of the tank cover Twist the hose end slightly to tighten the connection Caution should be used when using as a blower due to the powerful force of air when using certain attachmen...

Страница 7: ...cessory from end of hose With hose connected to tank inlet and front of unit facing you wrap hose around top of the tank cover in a clockwise direction Secure end of hose by clipping it in the hose ho...

Страница 8: ...y MONTHLY 1 Cleaning Inspect and clean all areas of the vacuum including the inside of the tank TROUBLESHOOTING ISSUE POSSIBLE CAUSE S CORRECTIVE ACTION Parts accessories missing 1 Packed in tank 1 Ch...

Отзывы: