PAGE 4 OF 12
0423
MODEL
H-86
H-87
H-89
REPAIR KIT
H-204
H-173
H-174
REPLACING TEFLON ROLL
1. Turn off power and unplug sealer.
2. Remove pressing plate and loosen teflon clips.
(See Figure 7)
3. Cut off a new section of teflon tape. Replace
pressing plate and tape.
4. Adjust teflon screw to tighten teflon roll. (See Figure 8)
5. Tighten teflon clips.
REPLACING HEATING ELEMENT
1. Turn off power and unplug sealer. Release teflon clips.
2. Remove screws to release heating element.
3. Remove old heating element and replace with the
new one.
4. Reattach and tighten the teflon tape.
ADDITIONAL INFORMATION
• Always keep the sealing platform clean. Remove
any residue (typically overheated plastic) from the
teflon barrier tape.
• Clean the sealing platform with a dry cloth. Do not
use water or solvents.
• A short circuit will occur if the bottom teflon tape
strip wears out. Each time you replace the heating
element or the top teflon tape, check the bottom
teflon tape for wear or damage.
• Only use Uline replacement parts.
• A worn rubber pressure pad (under the handle) will
influence the quality of the seal. The rubber pad
should be periodically checked for uneven wear.
• Potential risks of fire, electric shock, or injury to
persons are capable of occurring due to use of the
product. User is cautioned to place the product so it
is not likely that the product will be overturned.
• Eliminate the potential risks of electric shock during
the replacement of a lamp or cleaning of the
product by disconnecting the power supply cord.
• Close supervision is required when this product is
used near children.
REPLACEMENT PARTS
Figure 7
Teflon
Clips
Pressing
Plate
Figure 8
Teflon
Screw
Pressing
Plate
Teflon
Tape
Heating
Element
Teflon
Clip
1-800-295-5510