•  An extension cord must have adequate wire size 

(AWG or American Wire Gauge) for safety. The 

smaller the gauge number of the wire, the greater 

the capacity of the cable. An undersized cord 

will cause a drop in line voltage resulting in loss 

of power and overheating. When using more than 

one extension to make up total length, be sure 

each individual extension contains at least the 

minimum wire size. Following table shows correct 

size to use. If in doubt, use next heavier gauge. The 
smaller the gauge number, the heavier the cord.

Minimum Gauge for Cord Sets

Ampere Rating

Volts

Total Length of Cord

120V

25' 

50'

100'

150'

240V

50' 

100'

200'

300'

More 

Than

Not 

More 

Than

AWG

0

6

18

16

16

14

6

10

18

16

14

12

10

12

16

16

14

12

12

13

14

12

Not 

Recommended

WARNING: Always wear proper personal 
hearing protection that conforms to ANSI S12.6 
(S3.19) during use. Under some conditions and 

duration of use, noise from this product may 
contribute to hearing loss.

WARNING: Always use safety goggles. Everyday 
eyeglasses are NOT safety goggles. Also use 
face or dust mask if area operation is dusty. 

Always wear certified safety equipment:

•  ANSI Z87.1 eye protection (CAN/CSA Z94.3)

•  ANSI S12.6 (S3.19) hearing protection

•  NIOSH/OSHA/MSHA respiratory protection

To reduce exposure to these chemicals, wear 
approved safety equipment such as dust masks that 
are specifically designed to filter out microscopic 

particles.

For convenience and safety, the following warning 
label is on vacuum:

WARNING: Servicing of double insulated wet/

dry vacuum in a double-insulated wet/dry 

vacuum, two systems of insulation are provided 
instead of grounding. No grounding means 
is provided on a double-insulated appliance, 
nor should a means for grounding be added. 
Servicing a double-insulated wet/dry vacuum 
requires extreme care and knowledge of the 
system and should be done only by qualied 
service personnel. Replacement parts for a 

double-insulated wet/dry vacuum must be 

identical to the parts they replace. Double-
insulated wet/dry vacuum is marked with 
words "double insulated" and the symbol 
(square within a square) may also be marked 

on the appliance. To reduce risk of injury 

from electrical shock, unplug power cord 
before servicing electrical parts of the wet/dry 
vacuum.

IMPORTANT: If supply cord is damaged, it must 
be replaced by manufacturer or its service 
agent or a similarly qualified person in order to 
avoid a hazard

IMPORTANT: Remove plug from socket before 
performing maintenance. Before using 
machine ensure frequency and voltage shown 

on the rating plate correspond with main 
voltage. Specications and details are subject 
to change without prior notice. The accessories 
shown in the pictures may vary from model to 

model.

IMPORTANT: Symbol on product or packaging 
indicates that product must not be treated 
as domestic refuse. Instead, it should be 
handed in to a collection point 
for the recycling of electrical and 

electronic components.

WARNING: To reduce the risk of injury, users 
must read instruction manual. Do not run 
unattended. Do not pick up flammable, 
combustible or hot materials. Do not use 
around explosive dust, liquids or vapors. 
Electrical devices produce arcs or sparks 
which can cause fire or explosion. Do not 
use at filling stations or anywhere gasoline is 
stored or dispensed. Do not vacuum toxic or 
carcinogenic materials or other  
health-endangering materials such as 
asbestos or pesticides. Always use proper eye 
and respiratory protection. To reduce risk of 
electrical shock, do not expose to rain. Store 
indoors. When servicing, use only identical 
replacement parts. Do not use as a step stool.

Содержание DEWALT H-8902

Страница 1: ...8902 DXV12P Power 120 V 60 Hz 10 A Motor Single Stage Tank Capacity 12 Gallon Hose 2 x 7 Power Cord 20 WARNING Use only extension cords that are rated for outdoor use Extension cords in poor conditio...

Страница 2: ...lative humidity of air is low This is only temporary and does not affect use of vacuum To reduce frequency of static shocks add moisture to air with a console installed humidifier or anti static hose...

Страница 3: ...nce nor should a means for grounding be added Servicing a double insulated wet dry vacuum requires extreme care and knowledge of the system and should be done only by qualied service personnel Replace...

Страница 4: ...ee Figure 3 WARNING To reduce risk of fire or explosion do not operate this vacuum in areas with flammable gases vapors or explosive dust in the air Flammable gases or vapors include but are not limit...

Страница 5: ...ted and misting may appear in exhaust air At this time dry or replace cartridge filter to eliminate misting and possible dripping of liquid around lid After completing a wet pick up job raise hose to...

Страница 6: ...nts in suitable drain After tank is empty return drain cap to its original position To continue use plug cord into wall outlet and turn on the unit See Figure 8 BLOWING OPERATION WARNING Always wear s...

Страница 7: ...and float Float prevents water from entering the impeller and damaging the motor The cage prevents fingers from touching the moving impeller IMPORTANT To avoid damage to blower wheel and motor always...

Отзывы: