General Precautions

Use this appliance for its intended purpose only and 
follow these general precautions along with those listed 
throughout this guide:

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Keep the unit unplugged throughout installation 

except during testing.

• Never remove the round grounding prong from 

the plug and never use a two-prong grounding 
adapter.

• Never use an extension cord to connect power to 

the unit.

• Always keep your working area dry. 

CAUTION

• Use care when moving and handling the unit. Use 

gloves to prevent personal injury from sharp edges.

• Do not lift the unit by the door or door handle.

• Do not install the unit behind closed doors or in any 

way that would obstruct airflow to the front grille, 
which may cause the unit to malfunction.

You have received a carton containing your CO29A or 
CO29FF Ice Maker/Refrigerator with a package inside 
containing a User Manual, a Product Registration Card 
and water connection parts. Complete and mail the 
Product Registration Card or register online at 
www.U-LineService.com. Once your unit is installed, keep 
the User Manual and this Installation Guide in a safe place 
for future reference.

CO29A/CO29FF units are available in vinyl clad cabinets 
with matching doors which have a slightly contoured 
handle across the top and are reversible. The doors have 
recessed front panels that will accept a custom 1/4 inch 
thick door panel. Units have two tempered glass shelves. 

Please carefully follow the directions that apply to your 
unit and your intended design.

Tools/Materials Required

• Screwdrivers — slotted and Phillips head

• 1/4-inch OD copper tubing and shut-off valve for water 

supply line

• 1/4-inch thick door panel material and cutting tools

Inspection

Unwrap and inspect the unit on a flat, level surface 
capable of supporting its entire weight.

Exterior Cleaning

(As Required)

Black and White Models:

Black and white surfaces may be cleaned with a mild 
detergent and warm water solution. Do not use solvent-
based or abrasive cleaners. Use a soft sponge and rinse 
with clean water. Wipe with a soft, clean towel to prevent 
water spotting.

2 Inspect and Plan

Содержание Combo CO29

Страница 1: ...com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CO29A and CO29FF Ice Maker Refrigerators I...

Страница 2: ...ction to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for ass...

Страница 3: ...d and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in...

Страница 4: ...t sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance for th...

Страница 5: ...from cabinet two screws See Figure 5 Remove screws on opposite side of cabinet Figure 6 Note that there may be a nut behind one or both screws on either side 4 Install hinge on opposite side bottom of...

Страница 6: ...1 Adjust door to assure proper seal Tighten upper and lower hinge screws securely 12 Replace three plastic plugs removed in Step 8 into holes on top of unit Replace screws in holes in bottom of unit o...

Страница 7: ...not weigh more than 20 lbs Door Panel Installation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head s...

Страница 8: ...screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follo...

Страница 9: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized rec...

Страница 10: ...ntangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop Grille In...

Страница 11: ...etween 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon...

Страница 12: ...n Problem Q Water does not appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more...