U-Line Combo CO29 Скачать руководство пользователя страница 1

www.U-LineService.com

Phone (414) 354-0300 • FAX (414) 354-7905

Service & Parts Tech Lines Phone (800) 779-2547 • FAX (414) 354-5696

[email protected]

©2005 U-Line Corporation

02/2005

CO29A and CO29FF
Ice Maker/Refrigerators

Installation Guide

 

Содержание Combo CO29

Страница 1: ...com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CO29A and CO29FF Ice Maker Refrigerators I...

Страница 2: ...ction to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for ass...

Страница 3: ...d and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in...

Страница 4: ...t sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance for th...

Страница 5: ...from cabinet two screws See Figure 5 Remove screws on opposite side of cabinet Figure 6 Note that there may be a nut behind one or both screws on either side 4 Install hinge on opposite side bottom of...

Страница 6: ...1 Adjust door to assure proper seal Tighten upper and lower hinge screws securely 12 Replace three plastic plugs removed in Step 8 into holes on top of unit Replace screws in holes in bottom of unit o...

Страница 7: ...not weigh more than 20 lbs Door Panel Installation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head s...

Страница 8: ...screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follo...

Страница 9: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized rec...

Страница 10: ...ntangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop Grille In...

Страница 11: ...etween 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon...

Страница 12: ...n Problem Q Water does not appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more...

Отзывы: