U-Line CO1224F Скачать руководство пользователя страница 34

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

U-Line Corporation (U-Line) Limited Warranty

One Year Limited Warranty 

For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the 
product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material 
cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-
Line under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service 
provided during normal business hours.

 

Available Second Year Limited Warranty 

Beyond the standard one year warranty outlined above, U-Line offers an extension of the one year warranty coverage for an additional 
second year from the date of purchase, free of charge. To take advantage of this second year warranty, you must register your product with 
U-Line within two months from the date of purchase at u-line.com providing proof of purchase. 

Five Year Sealed System Limited Warranty 

For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be 
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line 
under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service provided 
during normal business hours. 

Terms 

These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten 
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, 
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and 
maintained in accordance with the U-Line User Guide. 

The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any 
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of 
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal 
rights, and you may also have other rights which vary from state to state. 

Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of 

merchantability 

or any 

warranty 

fit for a particular purpose 

is limited to the duration of these warranties, and only extends to five years in duration for the parts 

described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitations may not apply to you. 

• The warranties only apply to the original purchaser and are non-transferable. 
• The second year and five year warranties cover products installed and used for normal residential or designated marine use only. 
• The warranties apply to units operated outside only if designed for outdoor use by model and serial number. 
• Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties. 
• The start of U-Line’s obligation is limited to four years after the shipment date from U-Line. 
• In-home instruction on how to use your product is not covered by these warranties. 
• Food, beverage, and medicine loss are not covered by these warranties. 
• If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip charge 

or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense. 

• Units purchased after use as floor displays

,

 and/or certified reconditioned units, are covered by the limited one year warranty only and 

no coverage is provided for cosmetic defects. 

• Signal issues related to Wi-Fi connectivity are not covered by these warranties. 

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 

8900 N. 55th Street, Milwaukee, WI 53223 • u-line.com • [email protected] • +1.800.779.2547

 

Copyright © 2014/2017 U-Line Corporation. All Rights Reserved. |  Publication Number 30379 |  10/2017 Rev. L 

                                            
                                            Warranty 1

Содержание CO1224F

Страница 1: ...USER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series CO1224F 24 Combo Model RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...ille Plinth Installation Door Swing Door Stop Door Adjust Free Standing Kit Operating Instructions First Use Control Operation Ice Sabbath Mode Airflow and Product Loading Interior Shelves Maintenance...

Страница 3: ...decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Pr...

Страница 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...n built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAUT...

Страница 9: ...duct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 24 610 mm 3 9 16 91 mm Not Including Handle...

Страница 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...

Страница 11: ...20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve in the supply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servici...

Страница 12: ...3 Locate water valve inlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn...

Страница 13: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...

Страница 14: ...eve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening...

Страница 15: ...e removing the grille When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing...

Страница 16: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...

Страница 17: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...

Страница 18: ...e door TO ALIGN AND ADJUST THE DOOR Remove grille Remove the grille see GRILLE PLINTH INSTALLATION section of this guide 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with c...

Страница 19: ...epare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws hol...

Страница 20: ...ly used when unit is not installed in surrounding cabinetry To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligni...

Страница 21: ...run overnight before loading with product U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the wat...

Страница 22: ...ROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine...

Страница 23: ...rtain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp inst...

Страница 24: ...llows 1 Remove the ice maker assembly cover 1 2 Find the adjusting screw on the ice maker assembly control box 2 The adjusting screw is just below the minus and plus signs on the control box CAUTION T...

Страница 25: ...nable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will flash briefly at the end of the ten second period 2 The interior light and control display 3 will go dark until us...

Страница 26: ...o perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporat...

Страница 27: ...t by pulling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place...

Страница 28: ...ass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finis...

Страница 29: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...

Страница 30: ...ntal conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins a...

Страница 31: ...ter is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be...

Страница 32: ...ll the components listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Co...

Страница 33: ...me the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Obstruction of front grille or condenser Digital Display Shows 1 16 or 99 A factory...

Страница 34: ...ranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied o...

Страница 35: ...YELLOW BLACK RED BROWN WHITE BROWN ORANGE ORANGE ORANGE BLACK BLACK BLACK BLACK BLACK GREEN W YELLOW BLACK YELLOW RED PURPLE WHITE WHITE WHITE WHITE LIGHT BLUE TO COMPRESSOR WHITE WHITE ORANGE PURPLE...

Страница 36: ...ment of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial nu...

Страница 37: ...dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may...

Страница 38: ...door assembly 80 54308 00 19 Freezer hinge assembly 80 54307 00 20 Gasket door 80 54213 00 21 Glass shelf 1 btm 80 54274 00 22 Glass shelf 1 top 80 54304 00 23 Grille w screws 80 54267 00 24 Handle w...

Страница 39: ...rts will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U...

Страница 40: ...ge Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near...

Страница 41: ...ctrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run winding r...

Страница 42: ...denser clean Confirm condenser fan operation Confirm proper compressor operating voltage Use 19 Component Testing in Service Mode Compressor not operating Confirm proper compressor operating voltage U...

Страница 43: ...If the unit does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode System...

Страница 44: ...onents have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to i...

Страница 45: ...perate normally Evaporator thermistor errors will be displayed in the error log Always assure that all thermistor connections are clean and dry Whenever opening a thermistor connection be sure to appl...

Страница 46: ...vigates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates light...

Страница 47: ...enter exit this mode hold the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will...

Страница 48: ...HERMISTOR 4 SET POINT MINUS OFFSET This shows the thermistor reading with offsets taken into account 12 ADJUST DEFROST INTERVAL 3 TO 24 HOURS This will adjust the interval between defrosts from 3 to 2...

Страница 49: ...t of time in minutes the fan will be delayed from starting from the beginning of a cooling cycle Adjustable 0 99 minutes 18 EVAPORATOR FAN DELAY IN MINUTES OFF Fan Delay Off is the amount of time in m...

Страница 50: ...ine button plug the unit into the appropriate power source 4 When the flashing digits appear 3 5 seconds use the up and down arrow buttons to select the appropriate model number See Above Model List 5...

Страница 51: ...rator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Страница 52: ...d in the Control Operations Service section This unit has three thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature within that zone...

Страница 53: ...F C 1224 RF 12 45 15 9 1215 1224 2218 2245 2224 2260 WC ZWC 12 45 45 7 1215 1224 2218 2245 2224 2260 R RSOD RDC BEV DC DWR RGL 12 45 42 6 CO29 F 12 18 n a CO1224 F 12 18 45 7 1224FZR Freezer Mode 6 4...

Страница 54: ...AN MOTOR 1 Disconnect unit from power source 2 Remove two screws from fan cover 3 Remove two screws holding fan bracket to liner 4 Unplug fan connection 5 Remove two nuts holding the fan to the fan br...

Страница 55: ...disconnected 2 Disconnect ice maker wire harness at plug 3 Disconnect thermistor plug 4 Remove water inlet tube 5 Remove three screws from wall of freezer housing 6 Remove ice maker assembly INSTALL I...

Отзывы: