ADA15IM
9
ADA SERIES
Door Alignment Check and Adjustment
IMPORTANT
IMPORTANT
Properly aligned, the door’s gasket should be firmly
in contact with the cabinet all the way around the
door (no gaps). Carefully examine the door’s gasket
to assure that it is firmly in contact with the
cabinet. Also make sure the door gasket is not
pinched on the hinge side of the door.
Figure 9
1. Loosen (do not remove) top
and bottom
hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
Door Reversal
To reverse the door, perform the following:
1. Remove the grille (two screws).
Figure 10
2. Remove top hinge from cabinet (three screws)
. Hold door to keep it from falling.
3. Lift the door off the bottom hinge.
Figure 11
4. Remove bottom hinge from cabinet (two screws)
.
ULIN_0143_A