0823 IH-10947

MAINTENANCE

PREVENTATIVE MAINTENANCE

CAUTION! Avoid contact with hot adhesive 
and glue gun tip. This may cause burns. Wear 

personal protective equipment per workplace 

and industry standard operating practices 
and procedures when using and cleaning 
or changing tip. Keep tip pointed away from 

body parts. 

To maintain proper operation, follow these steps: 

1.  Inspect nozzle tip daily. Ensure it is clean and clear 

of foreign matter. 

2.  Keep adhesive clean and free of airborne 

contaminants. 

AVOIDING PROBLEMS 

•  Ensure tool has reached temperature before 

operating. 

•  Do not leave tool switched on for long periods 

without use. If tool is not to be used for more than 

40 minutes, switch off and restart when required. 

•  Never lay tool on its side without optional side 

inserts. Always use tool stand provided. 

•  Only use adhesives designed for use with this tool. 

•  Never remove a partially used glue stick. This can 

lead to irreparable damage. 

•  Hot melt glue can be used instead of nails, 

staples, tapes and liquid glues. They should not 

be used in place of structural connections when 

heavy loads are involved. 

•  Do not use hot melt glue for objects that are 

exposed to extreme heat. Some glues that can 

be used in this tool will soften at 140ºF.

9.  Shut-off: Switch off tool and disconnect from the 

main supply (4). 

10.  Provided side inserts are attached to bottom of the 

tool stand. These can be installed to prevent the 

glue gun from lying completely flat. (See Figures 4-5)

11.  Optional: Extrude one adhesive stick to cool down 

the glue gun. 

OPERATION CONTINUED

Figure 4

Side Inserts

Bottom of 

Tool Stand

Figure 5

Side Inserts