background image

USER GUIDE

General Installation 1

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

General Installation

1. Use a level to confirm 

the unit is level. Level 
should be placed along 
top edge and side 
edge as shown. 

2. If the unit is not level, 

remove grille and 
adjust legs as 
necessary. Use 
included tool to adjust the height of the rear legs.

3. Confirm the unit is level after each adjustment and 

repeat the previous steps until the unit is level. 

INSTALLATION TIP

If the room floor is higher than the floor in the cutout 
opening, adjust the rear legs to achieve a total unit rear 
height of 1/8" (3 mm) less than the opening’s rear height. 
Shorten the unit height in the front by adjusting the front 
legs. This allows the unit to be gently tipped into the 
opening. Adjust the front legs to level the unit after it is 
correctly positioned in the opening.

INSTALLATION

1. Plug in the power/electrical cord.

2. Gently push the unit into position. Be careful not to 

entangle the cord.

3. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" (3 mm) below 
the countertop.

4. Install the anti-tip bracket.

5. Remove the interior packing material and wipe out the 

inside of the unit with a clean, water-dampened cloth.

1

2

Rotate Clockwise to raise rear leg.  

Rotate Counter-Clockwise to lower leg.

Rotate Front Legs to Adjust

Содержание 3036BVWCS00B

Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3036BVWC 36 Beverage Center RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...tion Anti Tip Bracket General Installation Integrated Panel Dimensions Integrated Grille Plinth Dimensions Integrated Panel Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Ope...

Страница 3: ...or additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u li...

Страница 4: ...jury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...Although not required you may choose to increase the overall cutout width for ease of installation The Modular 3000 Series units are engineered with a variety of adjustment features to help ensure a s...

Страница 9: ...line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 35 7 16 900 mm 33 11 16 to 34 11 16 856 mm to 881 mm 23 7 16 590 mm 3 5 8 to 4 5 8 92 to 118 mm I...

Страница 10: ...out Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1...

Страница 11: ...racket 5 8 16 mm deep into bottom of countertop Use the anti tip brackets as a template 4 Install 6 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT Side mount position is us...

Страница 12: ...ar height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the front le...

Страница 13: ...tant to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the diagram below Un...

Страница 14: ...y with the door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared overlay with insert must not weigh more than 20 lbs...

Страница 15: ...ERVICE Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Top Detail...

Страница 16: ...ed in the appropriate diagram on the next page Unit requires two complete panels 2 Optional Stain or Finish panel to desired stain or color Be sure to closely follow the instructions provided by the m...

Страница 17: ...ted Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integr...

Страница 18: ...ll integrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT INTEGRATED FRAME FLAT AND WITHOUT INTERF...

Страница 19: ...8 9 mm Height will vary from 3 5 16 84 mm to 4 5 16 110 mm based on your grille plinth strip base fascia height 2 Finish or stain your grille plinth strip base fascia panel to match your surrounding f...

Страница 20: ...pe will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to...

Страница 21: ...th strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fa...

Страница 22: ...re installed adjacent to a wall 1 4 6 mm clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated pan...

Страница 23: ...approximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should...

Страница 24: ...e that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This woul...

Страница 25: ...ove caps from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 i...

Страница 26: ...commends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default setting Follow the on screen prompt for language selecti...

Страница 27: ...l still maintain internal temperatures and set points To enable Sabbath Mode 1 Open the unit s door to activate the display 2 To access the Customer Menu hold for 5 seconds 3 Press or to scroll throug...

Страница 28: ...ding your unit leave space between the internal fans or vents and product loaded Anything blocking the required airflow circulation will result in uneven temperature distribution in the cabinet and ca...

Страница 29: ...he subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and...

Страница 30: ...he presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurate...

Страница 31: ...hat sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine...

Страница 32: ...n Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable...

Страница 33: ...so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustrations below Racks 1 through 5 Rack 6 Rack 7 La...

Страница 34: ...lf Height Shelf height may be adjusted to accommodate a broad range of product To alter your shelf spacing follow the instructions below 1 Remove the 4 Shelf clips from the shelf clip holes 2 Move she...

Страница 35: ...ip of the bin and raise the bin off the racks 3 Lift the rear of the bin off its seat on the rack 4 Pull the bin up and away from the racks To Reinstall 5 Fully extend the empty rack from within the c...

Страница 36: ...Scotchbrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be p...

Страница 37: ...he drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in...

Страница 38: ...hen necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any...

Страница 39: ...e cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engagem...

Страница 40: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...

Страница 41: ...are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum...

Страница 42: ...rature to a cooler set point Ensure unit is not located in excessive ambient temperatures or in direct sunlight Ensure the door is closing and sealing properly Ensure nothing is blocking the front gri...

Страница 43: ...a small increment see CONTROL OPERATION Causes which affect the internal temperatures of the cabinet include Temperature setting Ambient temperature where installed Installation in direct sunlight or...

Страница 44: ...ese models shall be one year from the date of installation This one year warranty does not apply to cosmetic damages proof of purchase may be required 4 The following conditions are excluded from this...

Страница 45: ...exclusive remedy under this warranty are set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or in...

Отзывы: