background image

USER GUIDE

Side-by-Side Installation 1

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Side-by-Side Installation

OTHER SITE REQUIREMENTS

Side-by-Side Installation

Units must operate from separate, properly grounded 
electrical receptacles placed according to each unit’s 
electrical specifications requirements.

Cutout width for a side-by-side installation is the total of 
the widths listed under Cutout Dimensions in each unit’s 
Installation Guide. Each door can be opened individually 
(one at a time) without interference.

However, to ensure unobstructed door swing (opening 
both doors at the same time), 1/4" (6.4 mm) of space 
needs to be maintained between the units.

Hinge-by-Hinge Installation (Mullion)

When installing two units hinge-by-hinge, 13/16" (22 mm) 
is required for integrated models. Additional space may be 
needed for any knobs, pulls or handles installed. 

Stainless steel models which include the standard stainless 
handle will require 4-9/16" (116 mm) to allow both doors 
to open to 90° at the same time.

1/4" (6 mm)

13/16" (22 mm)

4-9/16" (116 mm)

Содержание 3024FZR

Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3024FZR 24 Freezer RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...Requirements Electrical Cutout Dimensions Product Dimensions Side by Side Installation Anti Tip Bracket General Installation Integrated Grille Plinth Dimensions Grille Plinth Installation Door Swing...

Страница 3: ...ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all ava...

Страница 4: ...jury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...Adjustable doors leveling legs and grille will assist in fine tuning the installation All 3000 Series models fully integrate into overlay face frame inset or European frameless cabinet styles and inst...

Страница 9: ...sions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 24 610 mm 3 5 8 to 4 5 8 92 mm to 118 mm 33 11 16 to 34 11 16 856 to 881 mm 23 5 8 600...

Страница 10: ...out Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1...

Страница 11: ...using a 2 Phillips head screwdriver 3 Completely slide the unit into its position in the cabinet Be certain unit height is properly adjusted See GENERAL INSTALLATION 4 Open door completely Make certa...

Страница 12: ...EGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 5 Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into cabinetry frame using the anti tip bracket as a template 6 Install the 3 remaining...

Страница 13: ...tal unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust t...

Страница 14: ...or stain your grille plinth strip base fascia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish ap...

Страница 15: ...th strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fa...

Страница 16: ...allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm do...

Страница 17: ...approximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should...

Страница 18: ...to ensure that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit T...

Страница 19: ...E Alignment and Adjustment Procedure 1 Using a T 25 Torx Bit loosen each pair of Torx head screws on both the upper and lower hinge plates 2 Square and align door as necessary 3 Tighten Torx head scre...

Страница 20: ...commends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default setting Follow the on screen prompt for language selecti...

Страница 21: ...Display will count down from 5 to off ON Press and release Unit will come on immediately Adjust temp Press to set temperature Press to confirm temperature or wait 5 seconds Adjust lighting Press to ad...

Страница 22: ...an error notification will be displayed on the user interface See below for a list of errors NOTE Singe zone models will not use L left or R right zone indicators in error notification Setting Defaul...

Страница 23: ...ure press and select Actual Temps from the Customer Menu 2 Press or to scroll through available information 3 To return to the Customer Menu press and select Return to Menu Energy Saver Mode Energy Sa...

Страница 24: ...and Off To select a new sound level enter the Sound Level Menu from the Customer Menu 1 Press to select the current sound level 2 Press The current setting will begin to flash 3 Press or to select a d...

Страница 25: ...oring while settings are restored When restoration is complete Restoring will return to Restore To exit Factory Default press to select Return to Menu and press to confirm Help To access the Help Menu...

Страница 26: ...l still maintain internal temperatures and set points To enable Sabbath Mode 1 Open the unit s door to activate the display 2 To access the Customer Menu hold for 5 seconds 3 Press or to scroll throug...

Страница 27: ...low and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille internal fans or vents at any time or the unit will not perform as ex...

Страница 28: ...lems Using abrasive pads such as Scotchbrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete...

Страница 29: ...he drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in...

Страница 30: ...hen necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any...

Страница 31: ...below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes...

Страница 32: ...perature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illu...

Страница 33: ...r you can register on line at www u lineservice com 3 The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase a...

Страница 34: ...able warranty period 8 THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTIC...