USER GUIDE
Anti-Tip Bracket 1
u-line.com
SAFETY •
INSTALLATION & INTEGRATION
• OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
CAUTION
!
The anti-tip bracket must be installed to prevent
the unit from tipping when doors are fully
opened or excess weight is placed on the front of
the unit.
The anti-tip bracket has multiple mounting options.
Mounting will depend on your particular cabinet
configuration. Locate 3 #8x5/8" screws included with your
unit.
TOP MOUNT
For ease of installation, the anti-tip bracket is pre-installed
in the top mount position.
1. Completely slide the unit into its position in the
cabinet. Be certain unit height is properly adjusted.
(See GENERAL INSTALLATION).
2. Open door completely. Make certain door clears
surrounding cabinetry.
3. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8"
(16 mm) deep into bottom of counter top. Use the
anti-tip bracket as a template.
4. Install 3 #8x5/8" screws into the plate using a
#2 Phillips head screwdriver.
SIDE MOUNT
Side mount position is used when you are unable to mount
the bracket to the underside of your countertop.
1. Remove the pre-installed anti-tip bracket from the top
mount position and align the bracket to the hinge side
of the unit as shown above.
2. Reinstall the 2 #8x5/8" screws into the plate using a
#2 Phillips head screwdriver.
3. Completely slide the unit into its position in the
cabinet. Be certain unit height is properly adjusted.
(See GENERAL INSTALLATION).
4. Open door completely. Make certain door clears
surrounding cabinetry.
5. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8"
(16 mm) deep into cabinetry frame using the anti-tip
bracket as a template.
6. Install 3 #8x5/8" screws into the plate using a #2
Phillips head screwdriver.
Left Hinged Cabinet
Right Hinged Cabinet
12