background image

USER GUIDE

 Troubleshooting - Extended 3

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

MAIN CONTROL

The main control board is very robust and is rarely the 
cause of system issues. It is important to fully diagnose 
the board for any suspected failures before attempting to 
remove the board for replacement or service. Follow the 
guidelines below to fully test and diagnose the main 
control.

Power Fault

If the unit does not (or seems to not) power on, follow the 
flow chart below to help diagnose the issue. Before 
beginning it is important to first verify the unit is not 
simply set to sabbath mode.

Testing The Main Control

If the main control is suspected of being faulty, the 
following procedure should be performed to verify main 
control for functionality.

Relay & DC Outputs

One of the primary functions of the main control is to 
operate the multiple relay and DC outputs during each 
cycle. Verify proper operation of these relays using the 
following procedure.

1. Enter “Relay Toggle” through the service menu.

NOTICE

Frequently toggling the compressor relay could 
force the compressor into overload. The 
compressor will automatically deactivate during 
an overload and will remain deactivated until the 
overload switch cools. This could take some 
time. It is important to allow the compressor at 
least 5 minutes off time between relay cycles.

2. Toggle the relay. Its related component should 

activate / deactivate with the switching of the relay. If 
it does not, test component.

Other Suspected Main Control Faults

If other components have been ruled out as being faulty 
but the unit continues to have operating issues, it is most 
likely due to a configuration error. Configuration errors 
can be cleared by restoring the unit to its factory default 
setting. Factory defaults may be restored through the 
service menu.

CAUTION

!

Precautions must be taken while working with 
live electrical equipment. Be sure to follow 
proper safety procedures while performing tests 
on live systems.

Check Voltage 

At Wall Outlet

Verify Voltage At 

Main Control 

Voltage Input

Check Fuse F1

For Continuity

Replace 

Reed Switch

Replace Main

Board

Replace

Fuse

Replace

Power Cord

Alert Customer 

Of Power Failure

Is the Reed

Switch Operating

Properly?

Inspect 

Customer UI 

and Data Cable 

Connect Test Display 

Cycle Power And Check 

For Operation 

No Voltage

No Voltage

Voltage

Continuity

Operating

Not Operating

No Continuity

No

Yes

Voltage

Содержание 2260ZWC

Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 2000 Series 2260ZWC 60 cm Wine Cellar Model RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...ensions Integrated Panel Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Wood Trim Finishing Operating Instructions First Use Control Operation Sabbath Mode Airflow and Produc...

Страница 3: ...ORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference an...

Страница 4: ...oughout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been gi...

Страница 5: ...ever install or operate the unit behind closed doors Be sure front grille plinth strip base fascia is free of obstruction Obstructing free airflow can cause the unit to malfunction and will void the w...

Страница 6: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 7: ...F 10 C and 90 F 32 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Страница 8: ...g area dry If the detachable type electric supply cord is damaged it must be replaced by an equivalent cord available from the manufacturer or its service agent NOTICE Electrical installation must obs...

Страница 9: ...ides or rear However the front grille plinth strip base fascia must NOT be obstructed CAUTION Unit can NOT be installed behind a closed cabinet door U Line products are designed and manufactured to be...

Страница 10: ...ine com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 3 5 8 to 4 5 8 92 mm to 118 mm 33 11 16 to 34 11 16 856 mm to 881 mm 23 7 16 590 mm 23 5 8 600 mm...

Страница 11: ...out Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1...

Страница 12: ...m drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 4 Install 3 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT...

Страница 13: ...a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adju...

Страница 14: ...tant to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the appropriate diag...

Страница 15: ...erfectly with the door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared overlay with insert must not weigh more than...

Страница 16: ...AINTENANCE SERVICE Handleless Integrated Panel Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref...

Страница 17: ...e dimensions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Opt...

Страница 18: ...ted Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integr...

Страница 19: ...tended Integrated Panel Dimensions BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY PANEL FLAT AND WITHOUT INTERFERENCE 23 3 8 594 mm 3 4 20 mm Integrated Panel 32 7 8 to 33 7 8 834 mm to 86...

Страница 20: ...ia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish application and cure times 3 Apply double sid...

Страница 21: ...so be used U Line recommends the use of bar clamps to secure the panel to the door If using tape be certain the tape will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pil...

Страница 22: ...CE SERVICE 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 12 St...

Страница 23: ...e fascia When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille pl...

Страница 24: ...re installed adjacent to a wall 1 4 6 mm clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated pan...

Страница 25: ...approximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should...

Страница 26: ...e that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This woul...

Страница 27: ...ove caps from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 i...

Страница 28: ...aining or finishing to prevent permanent damage to the inner liner of the unit Allow stain or finish to dry thoroughly at least 24 hours for each coat following the product manufacturer s instructions...

Страница 29: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the f...

Страница 30: ...e lights Press and release Leave interior light on for 3 hours Adjust temperature Press and release The zone you are setting will have its light turned on top zone first Press to adjust set point temp...

Страница 31: ...tain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will...

Страница 32: ...er airflow to perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between...

Страница 33: ...he subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and...

Страница 34: ...he presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurate...

Страница 35: ...hat sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine...

Страница 36: ...n Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable...

Страница 37: ...tles so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustrations below Racks 1 through 5 Rack 6 Large...

Страница 38: ...ems Using abrasive pads such as ScotchBrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete...

Страница 39: ...he drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in...

Страница 40: ...hen necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any...

Страница 41: ...e cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engagem...

Страница 42: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...

Страница 43: ...s listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air...

Страница 44: ...r openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be ena...

Страница 45: ...unauthorized modification or misuse abuse of the product customer education calls food loss and spoilage door and water level adjustments except during the first 30 days from the date of installation...

Страница 46: ...INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE installation of the product or from any other cause whatsoever whether based on warranty express or implied or otherwise based on contract tort o...

Страница 47: ...TRAL WHITE 115V BLUE 220 240V TO COMPRESSOR LIGHT BLUE TO COMPRESSOR PURPLE W YELLOW PURPLE YELLOW EVAP VALVE EVAP VALVE NEUTRAL HOT RELAY EMBRACO COMPRESSOR GREEN or GREEN W YELLOW GROUND OVERLOAD CA...

Страница 48: ...roduct equipped with a drain pump the drain pump must be returned along with the unit regardless of the drain pump manufacturer To complete the damage claim process for the customer please forward the...

Страница 49: ...dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may...

Страница 50: ...r U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original...

Страница 51: ...ge Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near...

Страница 52: ...grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measur...

Страница 53: ...rification of temperature and thermistor performance can be identified by directly viewing thermistor readings in the service mode Component failure issues can be identified through service mode menu...

Страница 54: ...codes Refer to 14 Error Log in Service Mode Thermistor failure Check Error Log in Service Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adj...

Страница 55: ...r into overload The compressor will automatically deactivate during an overload and will remain deactivated until the overload switch cools This could take some time It is important to allow the compr...

Страница 56: ...l be displayed in the error log Evaporator Thermistor If the evaporator thermistor fails the unit will rely on a preset defrost time during defrost cycles The unit will otherwise operate normally Evap...

Страница 57: ...n CLR models LED activated with button activation 7 LED No button Illuminates with Hidden Button Illuminates with required displayed alerts 1 2 3 4 5 6 7 CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLA...

Страница 58: ...F while you placed the thermistor in an icebath the actual thermistor reading when viewing actual temperature would read 35 F In the unit this would cause the cabinet to push itself 3 cooler To view p...

Страница 59: ...t light icon to enter and save change 13 Adjust defrost duration 0 to 99 minutes Up down to select light icon to enter and save change 14 Display error log Use up down to access and light bulb key to...

Страница 60: ...HERMISTOR 4 OFFSET Call tech line before adjusting 9 VIEW THERMISTOR 2 SET POINT MINUS OFFSET 10 VIEW THERMISTOR 3 SET POINT MINUS OFFSET 11 VIEW THERMISTOR 4 SET POINT MINUS OFFSET 12 DEFROST INTERVA...

Страница 61: ...EFROST INFORMATION Displays the number of defrosts that have occurred in the past 24 hours 23 COMPRESSOR RUNTIME BASED ON LAST CYCLE This will show the number of minutes the compressor has run in the...

Страница 62: ...con Use the up down arrows to scroll to correct model number from chart Push and release the light icon Unit flashes OFF ON then locks in model 1000 MODEL 2000 120V MODEL 2000 230V MODEL 1215R 07 2218...

Страница 63: ...and is used for defrost purposes Thermistor three is located along the right hand side wall in the bottom zone It is used to maintain the operating temperature within that zone Thermistor four is loc...

Страница 64: ...ION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These units are automatic cycle defrost unit will defrost itself when the control sensor is satisfied of internal temperatures Defros...

Отзывы: