USER GUIDE
Service Mode 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Service Mode
SERVICE MODE QUICK GUIDE
Number
Service Mode Menu Item
To Navigate/Access
1
VIEW THERMISTOR #1 CABINET TEMP NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO
VIEW
2
VIEW THERMISTOR #
2
EVAPORATOR NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO
VIEW
3
VIEW THERMISTOR #
3
FREEZER NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
4
VIEW THERMISTOR #
4
ICE MAKER NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
5
ADJUST THERMISTOR #
1
OFFSET
CALL TECH LINE FOR ASSISTANCE
800 779 2547
6
ADJUST THERMISTOR #
2
OFFSET
CALL TECH LINE FOR ASSISTANCE
800 779 2547
7
ADJUST THERMISTOR #3 OFFSET
CALL TECH LINE FOR ASSISTANCE
800 779 2547
8
ADJUST THERMISTOR #
4
OFFSET
CALL TECH LINE FOR ASSISTANCE
800 779 2547
9
VIEW THERMISTOR #2 SETPOINT NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
10
VIEW THERMISTOR #3 SET POINT NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
11
VIEW THERMISTOR #4 SET POINT NO OFFSETS
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
12
ADJUST DEFROST INTERVAL
3
TO
12
HOURS
UP/DOWN TO SELECT, LIGHT ICON TO ENTER AND SAVE CHANGE
13
ADJUST DEFROST DURATION
0
TO
99
MINUTES
UP/DOWN TO SELECT, LIGHT ICON TO ENTER AND SAVE CHANGE
14
DISPLAY ERROR LOG
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW
15
CLEAR ERROR LOG
USE UP/DOWN TO ACCESS AND LIGHT BULB KEY TO CLEAR
16
VIEW THERMISTOR #
1
DIFFERENTIAL
DO NOT MAKE ANY CHANGES TO THIS
17
AN ON DELAY (START OF COOLING CYCLE)
UP/DOWN TO SELECT, LIGHT ICON TO ENTER AND SAVE CHANGE
18
FAN OFF DELAY (AFTER COOLING CYCLE STOPS)
UP/DOWN TO SELECT, LIGHT ICON TO ENTER AND SAVE CHANGE
19
COMPONENT TESTING (SEE SERVICE MODE)
USE UP/DOWN TO ACCESS, LIGHT BULB ICON TO TOGGLE ON/OFF
20
DISPLAY PROGRAMMED MODEL NUMBER
USE UP/DOWN TO ACCESS, LIGHT BULB ICON TO DISPLAY
21
LIGHT ALL LED SEGMENT’S OF DISPLAY (TEST)
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO VIEW
22
DISPLAY DEFROST CYCLES IN LAST
24
HOURS
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO VIEW
23
DISPLAYS LAST/CURRENT COMPRESSOR RUN TIME
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO VIEW
24
ACTIVATE DEFROST CYCLE
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO START
25
RESTORE FACTORY DEFAULTS
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO RESTORE
26
DISPLAY CONTROL BOARD SOFTWARE VERSION
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO VIEW
27
DISPLAY USER INTERFACE SOFTWARE VERSION
USE UP/DOWN TO ACCESS AND LIGHT BULB ICON TO VIEW
28
MONITOR UNIT FUNCTION THROUGH LAPTOP/PC
CALL TECH LINE FOR ASSISTANCE
800 779 2547
0
TO EXIT SERVICE MODE
USE UP/DOWN TO SCROLL AND LIGHT BULB ICON TO EXIT