8. Install retaining clip.

OUTDOOR MODELS

PREPARE PLUMBING

The water valve uses a standard 1/4" (6.35 mm) 
compression fitting. U-Line recommends using accessory 
water hook up kit – part # WATERHOOKUP. The kit 
includes a 10' (3 m) braided flexible water supply line and 
a brass hose fitting. When using a 1/4" (6.35 mm) O.D. 
soft copper supply line use the brass nut and sleeve 
included with the unit.

WARNING

!

Prior to installation, determine if this product 
contains a gravity style drain or factory installed 
drain pump. Products without a drain pump may 
only use a gravity style drain. Failure to connect 
water supply or drain line connections properly 
may result in water leakage, personal injury, 
and/or property damage. Disconnect power and 
turn off water to the unit before attempting to 
alter these connections. These connections are 
the responsibility of the owner and must be 
connected per local plumbing code. If you are 
uncertain of how to safely and properly install 
this product, contact a licensed plumber. 

Water Supply Connection

WARNING

!

Connect to potable water supply only.

CAUTION

!

Review, obey, and understand the local 
plumbing codes before you install your unit. 
Connect to the cold water supply. The water 
pressure should be between 20 and 120 psi (138 
and 827 kPa). The water line MUST have a shut-
off valve on the supply line.

CAUTION

!

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use tape or joint compound when 
attaching a braided flexible water supply line 
that includes a rubber gasket. The gasket 
provides an adequate seal – other materials 
could cause blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

CAUTION

!

Turn off water supply and disconnect electrical 
supply to unit prior to installation.

Use caution when handling back panel. The 
edges could be sharp.

Содержание 1024 BEV

Страница 1: ...QUICK START GUIDE 1000 Series CLR1215 115 V 60 Hz ...

Страница 2: ...additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be con...

Страница 3: ...peration 10 First Use 10 Ice 12 Sabbath Mode 13 Warranty This Quick Start Guide covers the basics of installation and general use of your product For more details see the complete User Guide Service Manual on u line com This product is eligible for an additional one year warranty at no charge when you register your product on u line com See complete warranty for details plus eligible 1 warranty wa...

Страница 4: ...signed to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is consid...

Страница 5: ...d is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4 6 35 mm compression fitting A 10 3 m braided flexible water supply line is included with the unit WARNING Prior to installation determine if this product contains a gravity style drain or factory installed dr...

Страница 6: ...sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the grille access panel in the front and the back panel 3 Locate water valve in the front of the unit and thread water supply line through Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve Normal o...

Страница 7: ... connected per local plumbing code If you are uncertain of how to safely and properly install this product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure should be between 20 and 120 psi 138 and 827 kPa The wat...

Страница 8: ...s not come into contact with any internal components other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 3 On the back panel break away filler feature in bushing with flat screwdriver 4 Thread water line through back panel hole with bushing 5 Turn ...

Страница 9: ... be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connections and fittings are free from leaks GRAVITY DRAIN A gravity drain may be used if Drain line has at least a 1 drop per 48 approximately 2 cm drop per 100 cm of run Drain line does not create tr...

Страница 10: ...or Swing Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance if installed next to a wall Allow for additional space for any knobs or pulls installed on the integrated panel frame Cold Wat...

Страница 11: ...l cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the counter top 4 Install the anti tip bracket 5 Remove interior packing material and wipe out the inside of the unit with a clean water dampe...

Страница 12: ...ect depth in order to avoid splits in the wood when hardwood is installed 11 Locate 6 of the 6x 1 1 4 32 mm screws provided with your unit 12 Using a Phillips screwdriver place one screw into each of the 6 pilot holes and screw down Do not overtighten screws 13 Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel 14 Remove clamps...

Страница 13: ...ion to stabilize for 24 hours before rechecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice cubes in any given batch will vary so it is necessary to choose cubes from the sample area for comparison when making adjustments Up Down Light Power Clean LED CONTROL FUNCTION GUIDE FUNCTION COMMAN...

Страница 14: ...at the default cube thickness 0 Your clear ice machine is pre set to produce ice between the optimal dimensions illustrated below Ice thickness adjustments are made using the control panel as follows 1 To enter the thickness adjustment mode Press and hold for 5 seconds The display will switch to 0 to confirm the thickness adjustment mode has been selected The factory setting is 0 Use to raise the ...

Страница 15: ...ss and hold the until the unit turns off 2 No new ice will form when the unit is off but previously made ice will still be accessible present for over 24 hours Pump equipped models will continue to remove water as needed even if the unit is off Sabbath Mode remains active until is pressed again and the unit turns on 1 2 3 4 5 6 7 Up Select Down Copyright 2014 2017 U Line Corporation All Rights Res...

Страница 16: ...r under these warranties or under any warranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied or statutory Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to y...

Отзывы: