![u-blox XPLR-IOT-1 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/u-blox/xplr-iot-1/xplr-iot-1_user-manual_829496031.webp)
XPLR-IOT-1 - User guide
UBX-21035674 - R03
USB connection
Page 31 of 42
C1-Public
4
USB connection
☞
Before plugging in XPLR-IOT-1 the first time, install the USB-UART device drivers. The drivers only
need to be installed once on a host PC.
1.
Download the USB-UART device drivers from the
2.
Unzip the file to a convenient location.
3.
Run the installer for your operating system.
4.
Connect XPLR-IOT-1 to a host PC using a USB A to micro-B cable.
5.
Turn on XPLR-IOT-1. Four virtual COM ports (VCP) will enumerate.
6.
Open Device Manager to view the installed ports.
Figure 25: UART Interface COM port assignments
shows the USB-UART interface assignments.
Module
USB-UART port
Initial data rate (bits/sec)
NORA-B106
Interface 0
115,200
SARA-R510S
Interface 1
115,200
NINA-W156
Interface 2
115,200
MAX-M10S
Interface 3
9,600
Table 20: USB-UART interface assignments
☞
COM port assignments differ among host PCs. Using
interface 0 is assigned to COM8.
7.
Open a terminal program, such as Putty
, to the virtual COM port (VCP) for
NORA-B1 (interface 0) with the settings 115,200 bps, no parity, 8 data bits, 1 stop bit. Set
terminal line endings to carriage return only (CR, or hex 0x0d).
NINA-W15, SARA-R5, and MAX-M10 are powered off by default. To use s-center, u-center, or
m-center, enter the following commands at the XPLR-IOT-1 command line interface:
•
Turn on NINA-W15 and direct UART prior to opening s-center
modules NINAW156 power_on
•
Turn on and enable SARA-R5 prior to opening m-center
modules SARAR5 power_on
•
Turn on MAX-M10 and direct UART prior to opening u-center
modules MAXM10S power_on